11. OPTIONS AND PERIPHERAL EQUIPMENT
11 - 10
11.2 Regenerative options
CAUTION
Do not use servo amplifiers with regenerative options other than the combinations
specified below.
Otherwise, it may cause a fire.
11.2.1 Combination and regenerative power
The power values in the table are resistor-generated powers and not rated powers.
(1) 200 V class
Servo
amplifier
Regenerative power [W]
Built-in
regenerative
resistor
MR-RB032
[40
Ω
]
MR-RB12
[40
Ω
]
MR-RB30
[13
Ω
]
MR-RB3N
[9
Ω
]
MR-RB31
[6.7
Ω
]
MR-RB32
[40
Ω
]
(Note 1)
MR-RB50
[13
Ω
]
(Note 1)
MR-RB5N
[9
Ω
]
(Note 1)
MR-RB51
[6.7
Ω
]
MR-J4-10B
(-RJ)
30
MR-J4-20B
(-RJ)
10
30
100
MR-J4-40B
(-RJ)
10
30
100
MR-J4-60B
(-RJ)
10
30
100
MR-J4-70B
(-RJ)
20 30 100 300
MR-J4-100B
(-RJ)
20 30 100 300
MR-J4-200B
(-RJ)
100 300 500
MR-J4-350B
(-RJ)
100
300
500
MR-J4-500B
(-RJ)
130
300
500
MR-J4-700B
(-RJ)
170
300
500
Servo
amplifier
(Note 2) Regenerative power [W]
External regenerative
resistor (accessory)
MR-RB5R
[3.2
Ω
]
MR-RB9F
[3
Ω
]
MR-RB9T
[2.5
Ω
]
MR-J4-11KB
(-RJ)
500 (800)
500
(800)
MR-J4-15KB
(-RJ)
850 (1300)
850
(1300)
MR-J4-22KB
(-RJ)
850 (1300)
850
(1300)
Note 1. Always install a cooling fan.
2. Values in parentheses assume the installation of a cooling fan.
Summary of Contents for MR-J4-100B(-RJ)
Page 17: ...8 MEMO ...
Page 143: ...4 STARTUP 4 20 MEMO ...
Page 199: ...5 PARAMETERS 5 56 MEMO ...
Page 227: ...6 NORMAL GAIN ADJUSTMENT 6 28 MEMO ...
Page 281: ...8 TROUBLESHOOTING 8 16 MEMO ...
Page 303: ...9 DIMENSIONS 9 22 MEMO ...
Page 319: ...10 CHARACTERISTICS 10 16 MEMO ...
Page 429: ...11 OPTIONS AND PERIPHERAL EQUIPMENT 11 110 MEMO ...
Page 435: ...12 ABSOLUTE POSITION DETECTION SYSTEM 12 6 MEMO ...
Page 483: ...14 USING A LINEAR SERVO MOTOR 14 34 MEMO ...
Page 531: ...16 FULLY CLOSED LOOP SYSTEM 16 26 MEMO ...
Page 613: ...17 APPLICATION OF FUNCTIONS 17 82 MEMO ...
Page 654: ...APPENDIX App 41 ...