17. APPLICATION OF FUNCTIONS
17 - 38
Display
Name
Error detail
Corrective action example
C006
Amplifier command start
error
One-touch tuning was attempted to start in
the amplifier command method under the
following speed condition.
Servo motor speed: 20 r/min or higher
Execute the one-touch tuning in the amplifier
command method while the servo motor is
stopped.
C007 Amplifier
command
generation error
1. One-touch tuning was executed in the
amplifier command method when the
permissible travel distance is set to 100
pulses or less in the encoder pulse unit, or
the distance is set not to increase the
servo motor speed to 150 r/min (mm/s) (50
r/min for direct drive motor) or higher at the
time of load to motor inertia ratio
estimation.
Set a permissible travel distance to 100
pulses or more in the encoder pulse unit, or a
distance so as to increase the servo motor
speed to 150 r/min (mm/s) (50 r/min for direct
drive motor) or higher at the time of load to
motor inertia ratio estimation, and then
execute the one-touch tuning. Set a
permissible travel distance to four or more
revolutions as a guide value.
Load to motor inertia ratio will be estimated
when "0000" or "0001" is set in [Pr. PA08
Auto tuning mode] at the start of one-touch
tuning.
If the permissible travel distance is short and
the servo motor speed cannot be increased to
150 r/min (mm/s) (50 r/min for direct drive
motor) or higher, select "Auto tuning mode 2
(_ _ _ 2)", "Manual mode (_ _ _ 3)", or "2 gain
adjustment mode 2 (_ _ _ 4)" of "Gain
adjustment mode selection" in [Pr. PA08].
2. An overspeed alarm detection level is set
so that the servo motor speed becomes
150 r/min (mm/s) (50 r/min for direct drive
motor) or less at the time of load to motor
inertia ratio estimation.
When estimating the load to motor inertia
ratio, set the overspeed alarm detection level
so that the speed becomes 150 r/min or
more.
3. The torque limit has been set to 0.
Set the torque limit value to greater than 0.
C008
Stop signal
EM2 was turned off during one-touch tuning in
the amplifier command method.
Review the one-touch tuning start position
and permissible travel distance for the
amplifier command method.
After ensuring safety, turn on EM2.
C009
Parameter
Parameters for manufacturer setting have
been changed.
Return the parameters for manufacturer
setting to the initial values.
C00A
Alarm
One-touch tuning was attempted to start in
the amplifier command method during alarm
or warning.
Alarm or warning occurred during one-touch
tuning by the amplifier command method.
Start one-touch tuning when no alarm or
warning occurs.
Prevent alarm or warning from occurring
during one-touch tuning.
C00F One-touch
tuning
disabled
"One-touch tuning function selection" in [Pr.
PX13] is "Disabled (_ _ _ 0)".
Select "Enabled (_ _ _ 1)".
6) If an alarm occurs
If an alarm occurs during the one-touch tuning, the tuning will be forcibly terminated. Remove the
cause of the alarm and execute one-touch tuning again. When executing one-touch tuning in the
amplifier command method again, return the moving part to the tuning start position.
7) If a warning occurs
If a warning which continues the motor driving occurs during one-touch tuning by the user
command method, the tuning will be continued. If a warning which does not continue the motor
driving occurs during the tuning, one-touch tuning will be stopped.
One-touch tuning will be stopped when warning occurs during one-touch tuning by the amplifier
command method regardless of the warning type. Remove the cause of the warning, and return
the moving part to the tuning start position. Then, execute the tuning again.
Summary of Contents for MR-J4-100B(-RJ)
Page 17: ...8 MEMO ...
Page 143: ...4 STARTUP 4 20 MEMO ...
Page 199: ...5 PARAMETERS 5 56 MEMO ...
Page 227: ...6 NORMAL GAIN ADJUSTMENT 6 28 MEMO ...
Page 281: ...8 TROUBLESHOOTING 8 16 MEMO ...
Page 303: ...9 DIMENSIONS 9 22 MEMO ...
Page 319: ...10 CHARACTERISTICS 10 16 MEMO ...
Page 429: ...11 OPTIONS AND PERIPHERAL EQUIPMENT 11 110 MEMO ...
Page 435: ...12 ABSOLUTE POSITION DETECTION SYSTEM 12 6 MEMO ...
Page 483: ...14 USING A LINEAR SERVO MOTOR 14 34 MEMO ...
Page 531: ...16 FULLY CLOSED LOOP SYSTEM 16 26 MEMO ...
Page 613: ...17 APPLICATION OF FUNCTIONS 17 82 MEMO ...
Page 654: ...APPENDIX App 41 ...