17. APPLICATION OF FUNCTIONS
17 - 52
2) Switchable gain parameter
Loop gain
Before switching
After switching
Parameter Symbol
Name
Parameter Symbol
Name
Load to motor inertia
ratio/load to motor mass
ratio
PB06
GD2
Load to motor inertia
ratio/load to motor mass
ratio
PB29
GD2B
Load to motor inertia
ratio/load to motor mass
ratio after gain switching
Model loop gain
PB07
PG1
Model loop gain
PX12
PG1B
Model loop gain after gain
switching
Position loop gain
PB08
PG2
Position loop gain
PB30
PG2B
Position loop gain after
gain switching
Speed loop gain
PB09
VG2
Speed loop gain
PB31
VG2B
Speed loop gain after gain
switching
Speed integral
compensation
PB10 VIC
Speed
integral
compensation
PB32 VICB
Speed
integral
compensation after gain
switching
Vibration suppression
control 1 - Vibration
frequency
PB19 VRF11
Vibration
suppression
control 1 - Vibration
frequency
PB33 VRF11B
Vibration
suppression
control 1 - Vibration
frequency after gain
switching
Vibration suppression
control 1 - Resonance
frequency
PB20 VRF12
Vibration
suppression
control 1 - Resonance
frequency
PB34 VRF12B
Vibration
suppression
control 1 - Resonance
frequency after gain
switching
Vibration suppression
control 1 - Vibration
frequency damping
PB21 VRF13
Vibration
suppression
control 1 - Vibration
frequency damping
PB35 VRF13B
Vibration
suppression
control 1 - Vibration
frequency damping after
gain switching
Vibration suppression
control 1 - Resonance
frequency damping
PB22 VRF14
Vibration
suppression
control 1 - Resonance
frequency damping
PB36 VRF14B
Vibration
suppression
control 1 - Resonance
frequency damping after
gain switching
Vibration suppression
control 2 - Vibration
frequency
PX04 VRF21
Vibration
suppression
control 2 - Vibration
frequency
PX08 VRF21B
Vibration
suppression
control 2 - Vibration
frequency after gain
switching
Vibration suppression
control 2 - Resonance
frequency
PX05 VRF22
Vibration
suppression
control 2 - Resonance
frequency
PX09 VRF22B
Vibration
suppression
control 2 - Resonance
frequency after gain
switching
Vibration suppression
control 2 - Vibration
frequency damping
PX06 VRF23
Vibration
suppression
control 2 - Vibration
frequency damping
PX10 VRF23B
Vibration
suppression
control 2 - Vibration
frequency damping after
gain switching
Vibration suppression
control 2 - Resonance
frequency damping
PX07 VRF24
Vibration
suppression
control 2 - Resonance
frequency damping
PX11 VRF24B
Vibration
suppression
control 2 - Resonance
frequency damping after
gain switching
Summary of Contents for MR-J4-100B(-RJ)
Page 17: ...8 MEMO ...
Page 143: ...4 STARTUP 4 20 MEMO ...
Page 199: ...5 PARAMETERS 5 56 MEMO ...
Page 227: ...6 NORMAL GAIN ADJUSTMENT 6 28 MEMO ...
Page 281: ...8 TROUBLESHOOTING 8 16 MEMO ...
Page 303: ...9 DIMENSIONS 9 22 MEMO ...
Page 319: ...10 CHARACTERISTICS 10 16 MEMO ...
Page 429: ...11 OPTIONS AND PERIPHERAL EQUIPMENT 11 110 MEMO ...
Page 435: ...12 ABSOLUTE POSITION DETECTION SYSTEM 12 6 MEMO ...
Page 483: ...14 USING A LINEAR SERVO MOTOR 14 34 MEMO ...
Page 531: ...16 FULLY CLOSED LOOP SYSTEM 16 26 MEMO ...
Page 613: ...17 APPLICATION OF FUNCTIONS 17 82 MEMO ...
Page 654: ...APPENDIX App 41 ...