5. PARAMETERS
5 - 3
5.1.1 Basic setting parameters ([Pr. PA_ _ ])
No. Symbol
Name
Initial
value
Unit
Each/
Common
Operation
mode
Standard
F
ull.
Lin.
D.D.
PA01 **STY Operation
mode
1000h
Each
PA02 **REG Regenerative
option
0000h
Common
PA03
*ABS
Absolute position detection system
0000h
Each
PA04
*AOP1 Function selection A-1
2000h
Common
PA05 For manufacturer setting
10000
PA06
1
PA07
1
PA08
ATU
Auto tuning mode
0001h
Each
PA09
RSP
Auto tuning response
16
Each
PA10 INP In-position
range
1600 [pulse] Each
PA11 For manufacturer setting
1000.0
PA12
1000.0
PA13
0000h
PA14
*POL
Rotation direction selection/travel direction selection
0
Each
PA15
*ENR
Encoder output pulses
4000
[pulse/rev]
Each
PA16
*ENR2 Encoder output pulses 2
1
Each
PA17
**MSR
Servo motor series setting
0000h
Each
PA18
**MTY
Servo motor type setting
0000h
Each
PA19
*BLK
Parameter writing inhibit
00ABh
Each
PA20
*TDS
Tough drive setting
0000h
Each
PA21
*AOP3 Function selection A-3
0001h
Each
PA22
**PCS
Position control composition selection
0000h
Each
PA23
DRAT
Drive recorder arbitrary alarm trigger setting
0000h
Each
PA24
AOP4
Function selection A-4
0000h
Each
PA25 OTHOV One-touch tuning - Overshoot permissible level
0
[%]
Each
PA26 For manufacturer setting
0000h
PA27
0000h
PA28
0000h
PA29
0000h
PA30
0000h
PA31
0000h
PA32
0000h
Summary of Contents for MR-J4W2-0303B6
Page 39: ...2 INSTALLATION 2 8 MEMO ...
Page 97: ...4 STARTUP 4 20 MEMO ...
Page 181: ...6 NORMAL GAIN ADJUSTMENT 6 28 MEMO ...
Page 235: ...9 DIMENSIONS 9 6 MEMO ...
Page 245: ...10 CHARACTERISTICS 10 10 MEMO ...
Page 309: ...13 USING STO FUNCTION 13 14 MEMO ...
Page 365: ...15 USING A DIRECT DRIVE MOTOR 15 24 MEMO ...
Page 389: ...16 FULLY CLOSED LOOP SYSTEM 16 24 MEMO ...
Page 461: ...17 APPLICATION OF FUNCTIONS 17 72 MEMO ...
Page 556: ...APPENDIX App 41 ...
Page 585: ...MEMO ...