5. PARAMETERS
5 - 53
5.2.7 Linear servo motor/DD motor setting parameters ([Pr. PL_ _ ])
POINT
Linear servo motor/DD motor setting parameters ([Pr. PL_ _ ]) cannot be used
with MR-J4W2-0303B6 servo amplifiers.
No.
Symbol
Name and function
Initial
value
[unit]
Setting
range
Each/
Common
PL01
**LIT1
Linear servo motor/DD motor function selection 1
Select a magnetic pole detection timing of the linear servo motor/DD motor and stop
interval of the home position returning.
Refer to Name
and function
column.
Each
Setting
digit
Explanation
Initial
value
_ _ _ x
Linear servo motor/DD motor magnetic pole detection
selection
The setting value "0" will be enabled only with absolute
position linear encoders.
0: Magnetic pole detection disabled
1: Magnetic pole detection at first servo-on
5: Magnetic pole detection at every servo-on
1h
_ _ x _
For manufacturer setting
0h
_ x _ _
Stop interval selection at the home position return
Set a stop interval of the home position returning.
The digit is enabled only for linear servo motors.
0: 2
13
(= 8192) pulses
1: 2
17
(= 131072) pulses
2: 2
18
(= 262144) pulses
3: 2
20
(= 1048576) pulses
4: 2
22
(= 4194304) pulses
5: 2
24
(= 16777216) pulses
6: 2
26
(= 67108864) pulses
3h
x _ _ _
For manufacturer setting
0h
PL02
**LIM
Linear encoder resolution - Numerator
Set a linear encoder resolution in [Pr. PL02] and [Pr. PL03].
Set the numerator in [Pr. PL02].
This is enabled only for linear servo motors.
1000
[
μ
m]
1 to
65535
Each
PL03
**LID
Linear encoder resolution - Denominator
Set a linear encoder resolution in [Pr. PL02] and [Pr. PL03].
Set the denominator in [Pr. PL03].
This is enabled only for linear servo motors.
1000
[
μ
m]
1 to
65535
Each
Summary of Contents for MR-J4W2-0303B6
Page 39: ...2 INSTALLATION 2 8 MEMO ...
Page 97: ...4 STARTUP 4 20 MEMO ...
Page 181: ...6 NORMAL GAIN ADJUSTMENT 6 28 MEMO ...
Page 235: ...9 DIMENSIONS 9 6 MEMO ...
Page 245: ...10 CHARACTERISTICS 10 10 MEMO ...
Page 309: ...13 USING STO FUNCTION 13 14 MEMO ...
Page 365: ...15 USING A DIRECT DRIVE MOTOR 15 24 MEMO ...
Page 389: ...16 FULLY CLOSED LOOP SYSTEM 16 24 MEMO ...
Page 461: ...17 APPLICATION OF FUNCTIONS 17 72 MEMO ...
Page 556: ...APPENDIX App 41 ...
Page 585: ...MEMO ...