6. NORMAL GAIN ADJUSTMENT
6 - 12
Click "Start" with the amplifier command method selected in the servo-off, the servo-on will be
automatically enabled, and the one-touch tuning will start. In the one-touch tuning by the amplifier
command method, an optimum tuning command will be generated in the servo amplifier after servo-on.
Then, the servo motor will reciprocate, and the one-touch tuning will be executed. After the tuning is
completed or canceled, the servo amplifier will be the servo-off status. When the servo-on command is
inputted from outside, the amplifier will be the servo-on status.
After one-touch tuning is executed using the amplifier command method, control will not be performed
by commands from the controller. To return to the state in which control is performed by commands from
the controller, reset the controller or cycle the power.
During processing of one-touch tuning, the progress will be displayed as follows. Tuning will be
completed at 100%.