13. USING STO FUNCTION
13 - 10
13.3.4 External I/O signal connection example using a motion controller
POINT
This connection is for source interface. For the other I/O signals, refer to the
connection examples in section 3.2.2.
For MC-Y0B and PC-Y0B, design a sequence program to output MC-Y0B and
PC-Y0B after the servo motor stops.
This connection diagram is an example of STO circuit configured with a servo amplifier and motion
controller. Use the switch that complies with the requirement of ISO/EN ISO 13849-1 Category 3 PL d as an
emergency stop switch. This connection example complies with the requirement of ISO/EN ISO 13849-1
Category 3 PL d. The following shows an example of I/O (X and Y) signal assignment of the motion
controller safety signal module. For details, refer to the motion controller user’s manual.
Shut-off
signal (MC)
Shut-off verification
signal (M)
Shut-off verification
signal (PLC)
Shut-off
signal (PLC)
Door signal (PLC)
24 V
0 V
Control circuit
Servo amplifier
STOCOM
STO2
Servo motor
S1: STO shut-off switch (STO switch)
KM1: Magnetic contactor
EMG: Emergency stop switch
Door signal (MC)
Q17_DSCPU
0 V
24 V DC
0 V
24 V DC
Programmable
controller CPU
(iQ platform
compatible)
Motion controller
safety signal module
(Q173DSXY)
CPU
(iQ platform compatible)
S1
CN8
KM1
CN3
EM2
KM1
STO1
TOFB1
TOFCOM
TOFB2
EM2
M
B09
B1
B19
B20
B09
B1
B19
B20
A1
A1
PC-X00
PC-X01
PLC I/O
MC-X01
MC-Y0B
MC-X00
MC I/O
PC-Y0B
EMG
Summary of Contents for MR-J4W2-0303B6
Page 39: ...2 INSTALLATION 2 8 MEMO ...
Page 97: ...4 STARTUP 4 20 MEMO ...
Page 181: ...6 NORMAL GAIN ADJUSTMENT 6 28 MEMO ...
Page 235: ...9 DIMENSIONS 9 6 MEMO ...
Page 245: ...10 CHARACTERISTICS 10 10 MEMO ...
Page 309: ...13 USING STO FUNCTION 13 14 MEMO ...
Page 365: ...15 USING A DIRECT DRIVE MOTOR 15 24 MEMO ...
Page 389: ...16 FULLY CLOSED LOOP SYSTEM 16 24 MEMO ...
Page 461: ...17 APPLICATION OF FUNCTIONS 17 72 MEMO ...
Page 556: ...APPENDIX App 41 ...
Page 585: ...MEMO ...