14. USING A LINEAR SERVO MOTOR
14 - 30
(2) Calculation method of the amount of heat generated by the servo amplifier
Calculate the amount of heat generated by one servo amplifier from tables 14.3 and 14.4.
Table 14.3 Amount of heat generated by one servo
amplifier at rated output
Table 14.4 Amount of heat generated by one
servo amplifier for one linear servo motor
Servo amplifier
(Note) Servo amplifier-generated heat [W]
Servo motor
Servo amplifier-
generated heat [W]
(B)
With servo-off (C)
At rated output
MR-J4W2-22B 20
Sum of the total amount
of heat generated by the
servo amplifier for each
linear servo motor ((B) in
table 14.4) and the
amount of heat
generated by the servo
amplifier with servo-off
(C)
LM-H3P2A-07P-BSS0
35
MR-J4W2-44B 20
LM-H3P3A-12P-CSS0
35
MR-J4W2-77B 20
LM-H3P3B-24P-CSS0
50
MR-J4W2-1010B 20
LM-H3P3C-36P-CSS0
75
MR-J4W3-222B 20
LM-H3P7A-24P-ASS0
50
MR-J4W3-444B 25
LM-U2PAB-05M-0SS0
25
LM-U2PAD-10M-0SS0
35
LM-U2PAF-15M-0SS0
35
Note.
Heat generated during regeneration is not included in the servo
amplifier-generated heat. To calculate heat generated by the
regenerative option, refer to section 11.2.
LM-U2PBB-07M-1SS0
25
LM-U2PBD-15M-1SS0
40
LM-U2PBF-22M-1SS0
50
LM-K2P1A-01M-2SS1
35
LM-K2P2A-02M-1SS1
50
Calculate the amount of heat generated by the servo amplifier with equation 10.2 in (2) in section 10.2.
Summary of Contents for MR-J4W2-0303B6
Page 39: ...2 INSTALLATION 2 8 MEMO ...
Page 97: ...4 STARTUP 4 20 MEMO ...
Page 181: ...6 NORMAL GAIN ADJUSTMENT 6 28 MEMO ...
Page 235: ...9 DIMENSIONS 9 6 MEMO ...
Page 245: ...10 CHARACTERISTICS 10 10 MEMO ...
Page 309: ...13 USING STO FUNCTION 13 14 MEMO ...
Page 365: ...15 USING A DIRECT DRIVE MOTOR 15 24 MEMO ...
Page 389: ...16 FULLY CLOSED LOOP SYSTEM 16 24 MEMO ...
Page 461: ...17 APPLICATION OF FUNCTIONS 17 72 MEMO ...
Page 556: ...APPENDIX App 41 ...
Page 585: ...MEMO ...