15. USING A DIRECT DRIVE MOTOR
15 - 2
The following shows the differences between the direct drive motor and the rotary servo motor.
Category Item
Differences
Remark
Direct drive motor
Rotary servo motor
External I/O signal
FLS (Upper stroke limit),
RLS (Lower stroke limit)
Required (for
magnetic pole
detection)
Not required
Automatically turns on in the
parameter setting.
Motor pole
adjustment
Magnetic pole detection
Required
Not required
(default setting)
Automatically executed at the first
servo-on after the power is turned
on.
For the absolute position detection
system, [Pr. PL01] can disable the
magnetic pole detection. (Refer to
(3) (b) of 15.3.2.)
Absolute position
detection system
Absolute position encoder
battery
1 battery case (MR-
BT6VCASE) and 5 batteries
(MR-BAT6V1)
Required
Required
The number of connectable direct
drive motors is limited. Refer to
section 11.3 for details.
Absolute position storage
unit
(MR-BTAS01)
Required Not
required