15. USING A DIRECT DRIVE MOTOR
15 - 17
(b) Speed deviation error detection
Set [Pr. PL04] to "_ _ _ 2" to enable the speed deviation error detection.
[Pr. PL04]
Speed deviation error detection enabled
2
When you compare the model feedback speed ( 3)) and the feedback speed ( 4)) in figure 15.1, if
the deviation is more than the value of [Pr. PL06 Speed deviation error detection level] (1 r/min to
2000 r/min), [AL. 42.2 Servo control error by speed deviation] will occur and the linear servo motor
will stop. The initial value of this detection level is 100 r/min. Replace the set value as required.
(c) Torque deviation error detection level
Set [Pr. PL04] to "_ _ _ 4" to enable the torque deviation error detection.
[Pr. PL04]
Torque deviation error detection enabled
4
When you compare the command torque ( 5)) and the feedback torque ( 6)) in figure 15.1, if the
deviation is more than the value of [Pr. PL07 Torque/thrust deviation error detection level] (1% to
1000%), [AL. 42.3 Servo control error by torque/thrust deviation] will occur and the linear servo
motor will stop. The initial value of this detection level is 100%. Replace the set value as required.
(d) Detecting multiple deviation errors
When setting [Pr. PL04] as shown below, multiple deviation errors can be detected. For the error
detection methods, refer to (1) (a), (b), (c) in this section.
[Pr. PL04]
Position deviation
error detection
Setting
value
Speed deviation
error detection
Torque deviation
error detection
1
5
6
7
3
2
4
Summary of Contents for MR-J4W2-0303B6
Page 39: ...2 INSTALLATION 2 8 MEMO ...
Page 97: ...4 STARTUP 4 20 MEMO ...
Page 181: ...6 NORMAL GAIN ADJUSTMENT 6 28 MEMO ...
Page 235: ...9 DIMENSIONS 9 6 MEMO ...
Page 245: ...10 CHARACTERISTICS 10 10 MEMO ...
Page 309: ...13 USING STO FUNCTION 13 14 MEMO ...
Page 365: ...15 USING A DIRECT DRIVE MOTOR 15 24 MEMO ...
Page 389: ...16 FULLY CLOSED LOOP SYSTEM 16 24 MEMO ...
Page 461: ...17 APPLICATION OF FUNCTIONS 17 72 MEMO ...
Page 556: ...APPENDIX App 41 ...
Page 585: ...MEMO ...