17. APPLICATION OF FUNCTIONS
17 - 53
(d) Gain switching procedure
This operation will be described by way of setting examples.
1) When you choose switching by control command from the controller
a) Setting example
Parameter Symbol
Name
Setting
value
Unit
PB06
GD2
Load to motor inertia ratio/load to
motor mass ratio
4.00 [Multiplier]
PB07
PG1
Model loop gain
100
[rad/s]
PB08
PG2
Position loop gain
120
[rad/s]
PB09
VG2
Speed loop gain
3000
[rad/s]
PB10
VIC
Speed integral compensation
20
[ms]
PB19
VRF11 Vibration suppression control 1 -
Vibration frequency
50 [Hz]
PB20
VRF12 Vibration suppression control 1 -
Resonance frequency
50 [Hz]
PB21
VRF13 Vibration suppression control 1 -
Vibration frequency damping
0.20
PB22
VRF14 Vibration suppression control 1 -
Resonance frequency damping
0.20
PX04
VRF21 Vibration suppression control 2 -
Vibration frequency
20 [Hz]
PX05
VRF22 Vibration suppression control 2 -
Resonance frequency
20 [Hz]
PX06
VRF23 Vibration suppression control 2 -
Vibration frequency damping
0.10
PX07
VRF24 Vibration suppression control 2 -
Resonance frequency damping
0.10
PB29
GD2B
Load to motor inertia ratio/load to
motor mass ratio after gain
switching
10.00 [Multiplier]
PX12
PG1B
Model loop gain after gain
switching
50 [rad/s]
PB30
PG2B
Position loop gain after gain
switching
84 [rad/s]
PB31
VG2B
Speed loop gain after gain
switching
4000 [rad/s]
PB32
VICB
Speed integral compensation after
gain switching
50 [ms]
PB26
CDP
Gain switching function
0001
(Switch by control command
from the controller.)
PB28
CDT
Gain switching time constant
100
[ms]
PB33
VRF11B Vibration suppression control 1 -
Vibration frequency after gain
switching
60 [Hz]
PB34
VRF12B Vibration suppression control 1 -
Resonance frequency after gain
switching
60 [Hz]
PB35
VRF13B Vibration suppression control 1 -
Vibration frequency damping after
gain switching
0.15
PB36
VRF14B Vibration suppression control 1 -
Resonance frequency damping
after gain switching
0.15
PX08
VRF21B Vibration suppression control 2 -
Vibration frequency after gain
switching
30 [Hz]
PX09
VRF22B Vibration suppression control 2 -
Resonance frequency after gain
switching
30 [Hz]
Summary of Contents for MR-J4W2-0303B6
Page 39: ...2 INSTALLATION 2 8 MEMO ...
Page 97: ...4 STARTUP 4 20 MEMO ...
Page 181: ...6 NORMAL GAIN ADJUSTMENT 6 28 MEMO ...
Page 235: ...9 DIMENSIONS 9 6 MEMO ...
Page 245: ...10 CHARACTERISTICS 10 10 MEMO ...
Page 309: ...13 USING STO FUNCTION 13 14 MEMO ...
Page 365: ...15 USING A DIRECT DRIVE MOTOR 15 24 MEMO ...
Page 389: ...16 FULLY CLOSED LOOP SYSTEM 16 24 MEMO ...
Page 461: ...17 APPLICATION OF FUNCTIONS 17 72 MEMO ...
Page 556: ...APPENDIX App 41 ...
Page 585: ...MEMO ...