4. STARTUP
4 - 11
4.3.2 Scrolling display
Displaying the status of each axis in rotation enables you to check the status of all axes.
(1) Normal display
When there is no alarm, the status of all axes are displayed in rotation.
A-axis status
After 1.6 s
Blank
After 0.2 s
B-axis status
After 1.6 s
Blank
After 0.2 s
A-axis status
After 1.6 s
Blank
After 0.2 s
B-axis status
After 1.6 s
Blank
MR-J4 2-axis
servo amplifier
Status
(1 digit)
Axis No.
(2 digits)
"b"
"C"
"d"
: Indicates ready-off and servo-off status.
: Indicates ready-on and servo-off status.
: Indicates ready-on and servo-on status.
After 0.2 s
A-axis status
After 1.6 s
Blank
After 0.2 s
B-axis status
After 1.6 s
Blank
After 0.2 s
C-axis status
After 1.6 s
Blank
After 0.2 s
After 1.6 s
Blank
MR-J4 3-axis
servo amplifier
After 0.2 s
(2) Alarm display
When an alarm occurs, the alarm number (two digits) and the alarm detail (one digit) are displayed
following the status display. For example, the following shows when [AL. 16 Encoder initial
communication error 1] is occurring at the A-axis, and [AL. 32 Overcurrent] is occurring at the B-axis
simultaneously.
A-axis status
After 0.8 s
After 0.8 s
Blank
After 0.2 s
B-axis status
After 0.8 s
B-axis alarm
No.
After 0.8 s
Blank
After 0.2 s
Status
(1 digit)
Axis No.
(2 digits)
"n": Indicates that an alarm is occurring.
Alarm detail
(1 digit)
Alarm No.
(2 digits)
A-axis alarm
No.
MR-J4 2-axis
servo amplifier
Summary of Contents for MR-J4W2-0303B6
Page 39: ...2 INSTALLATION 2 8 MEMO ...
Page 97: ...4 STARTUP 4 20 MEMO ...
Page 181: ...6 NORMAL GAIN ADJUSTMENT 6 28 MEMO ...
Page 235: ...9 DIMENSIONS 9 6 MEMO ...
Page 245: ...10 CHARACTERISTICS 10 10 MEMO ...
Page 309: ...13 USING STO FUNCTION 13 14 MEMO ...
Page 365: ...15 USING A DIRECT DRIVE MOTOR 15 24 MEMO ...
Page 389: ...16 FULLY CLOSED LOOP SYSTEM 16 24 MEMO ...
Page 461: ...17 APPLICATION OF FUNCTIONS 17 72 MEMO ...
Page 556: ...APPENDIX App 41 ...
Page 585: ...MEMO ...