3. SIGNALS AND WIRING
3 - 11
3.3.3 Wiring CNP1, CNP2, and CNP3
POINT
For the wire sizes used for wiring, refer to section 11.5.
(1) Connector
Servo amplifier
CNP1
CNP2
CNP3A
CNP3B
CNP3C (Note)
Note. For the MR-J4 3-axis servo amplifier
Table 3.1 Connector and applicable wire
Connector Receptacle
assembly
Applicable wire
size
Stripped length
[mm]
Open tool
Manufacturer
CNP1
03JFAT-SAXGFK-43
AWG 16 to 14
11.5
J-FAT-OT-EXL (big size
side)
JST
CNP2
06JFAT-SAXYGG-F-
KK
AWG 16 to 14
9
J-FAT-OT-EXL (small size
side)
CNP3A
CNP3B
CNP3C
04JFAT-SAGG-G-KK
AWG 18 to 14
9
J-FAT-OT-EXL (small size
side)
(2) Cable connection procedure
(a) Cable making
Refer to table 3.1 for stripped length of cable insulator. The appropriate stripped length of cables
depends on their type, etc. Set the length considering their status.
Insulator
Core
Stripped length
Twist strands slightly and straighten them as follows.
Loose and bent strands
Twist and straighten
the strands.
Summary of Contents for MR-J4W2
Page 9: ...A 8 MEMO ...
Page 17: ...8 MEMO ...
Page 31: ...1 FUNCTIONS AND CONFIGURATION 1 14 MEMO ...
Page 95: ...4 STARTUP 4 20 MEMO ...
Page 169: ...6 NORMAL GAIN ADJUSTMENT 6 20 MEMO ...
Page 201: ...7 SPECIAL ADJUSTMENT FUNCTIONS 7 32 MEMO ...
Page 213: ...8 TROUBLESHOOTING 8 12 MEMO ...
Page 219: ...9 OUTLINE DRAWINGS 9 6 MEMO ...
Page 229: ...10 CHARACTERISTICS 10 10 MEMO ...
Page 295: ...13 USING STO FUNCTION 13 14 MEMO ...
Page 327: ...14 USING A LINEAR SERVO MOTOR 14 32 MEMO ...
Page 371: ...16 FULLY CLOSED LOOP SYSTEM 16 24 MEMO ...
Page 521: ...APPENDIX App 38 ...
Page 537: ...MEMO ...
Page 541: ......