3. SIGNALS AND WIRING
3 - 24
(2) When the forced stop deceleration function is not enabled
When an all-axis stop alarm occur, all axes will be the operation status below. When a corresponding
axis stop alarm occurs, only the axis will be the operation status below. You can normally operate the
axis that any alarm is not occurring.
MBR
(Electromagnetic
brake interlock)
ON
OFF
ON (no alarm)
OFF (alarm)
Base circuit
(Energy supply to
the servo motor)
ON
OFF
Servo amplifier
display
0 r/min
Servo motor speed
CALM (AND malfunction)
No alarm
Alarm No.
Braking by the dynamic brake
Dynamic brake
+ Braking by the electromagnetic brake
Operation delay time of the electromagnetic brake
Alarm occurrence
(3) When SSCNET III/H communication shut-off occurs
When SSCNET III/H communication is broken, all axes will be the operation status below. The dynamic
brake may operate depending on the communication shut-off status.
MBR
(Electromagnetic
brake interlock)
ON
OFF
ON (no alarm)
OFF (alarm)
Base circuit
(Energy supply to
the servo motor)
ON
OFF
Servo amplifier
display
0 r/min
Servo motor speed
CALM (AND malfunction)
AA
No alarm (d1 or E7)
SSCNET III/H communication
has broken.
(Note 1)
Model speed command 0
and equal to or less than
zero speed
(Note 2)
Note 1. The model speed command is a speed command generated in the servo amplifier for forced stop
deceleration of the servo motor.
2. This is for when the electronic dynamic brake is enabled with [Pr. PF06] while a certain servo motor is
used. If the servo motor speed is 5 r/min or higher, the electronic dynamic brake will operate continuously
for the time period set in [Pr. PF12].
Summary of Contents for MR-J4W2
Page 9: ...A 8 MEMO ...
Page 17: ...8 MEMO ...
Page 31: ...1 FUNCTIONS AND CONFIGURATION 1 14 MEMO ...
Page 95: ...4 STARTUP 4 20 MEMO ...
Page 169: ...6 NORMAL GAIN ADJUSTMENT 6 20 MEMO ...
Page 201: ...7 SPECIAL ADJUSTMENT FUNCTIONS 7 32 MEMO ...
Page 213: ...8 TROUBLESHOOTING 8 12 MEMO ...
Page 219: ...9 OUTLINE DRAWINGS 9 6 MEMO ...
Page 229: ...10 CHARACTERISTICS 10 10 MEMO ...
Page 295: ...13 USING STO FUNCTION 13 14 MEMO ...
Page 327: ...14 USING A LINEAR SERVO MOTOR 14 32 MEMO ...
Page 371: ...16 FULLY CLOSED LOOP SYSTEM 16 24 MEMO ...
Page 521: ...APPENDIX App 38 ...
Page 537: ...MEMO ...
Page 541: ......