4. STARTUP
4 - 37
(4) Motor-less operation
Without connecting the servo motor, output signals or status display can be provided in response to the
input device as if the servo motor is actually running. This operation can be used to check the sequence
of a controller or the like.
(a) Start of motor-less operation
After setting "_ _ _ 1" in [Pr. PC60], cycle the power. After that, perform external operation as in
ordinary operation.
(b) Termination of motor-less operation
To terminate the motor-less operation, set [Pr. PC60] to "_ _ _ 0" and then turn the power off.
(5) Program operation
Positioning operation can be performed in two or more operation patterns combined, without using a
controller. Use this operation with the forced stop reset. This operation may be used independently of
whether servo-on or servo-off and whether a controller is connected or not.
Exercise control on the program operation screen of MR Configurator2. For details, refer to Help of MR
Configurator2.
Operation Screen
control
Start
Click "Operation start".
Stop Click
"Stop".
Forced stop
Click "Forced Stop".
(6) Output signal (DO) forced output
Output signals can be switched on/off forcibly independently of the servo status. This function is used for
output signal wiring check, etc. Exercise control on the DO forced output screen of MR Configurator2.
Summary of Contents for MR-JE-_A
Page 9: ...A 8 MEMO ...
Page 15: ...6 MEMO ...
Page 29: ...1 FUNCTIONS AND CONFIGURATION 1 14 MEMO ...
Page 139: ...4 STARTUP 4 38 MEMO ...
Page 187: ...5 PARAMETERS 5 48 MEMO ...
Page 221: ...6 NORMAL GAIN ADJUSTMENT 6 34 MEMO ...
Page 259: ...8 TROUBLESHOOTING 8 8 MEMO ...
Page 265: ...9 DIMENSIONS 9 6 MEMO ...
Page 273: ...10 CHARACTERISTICS 10 8 MEMO ...
Page 339: ...12 COMMUNICATION FUNCTION MITSUBISHI ELECTRIC GENERAL PURPOSE AC SERVO PROTOCOL 12 34 MEMO ...