5. PARAMETERS
5 - 22
No./symbol/
name
Setting
digit
Function
Initial
value
[unit]
Control mode
P S T
PB19
VRF11
Vibration
suppression
control 1 -
Vibration
frequency
Set the vibration frequency for vibration suppression control 1 to suppress low-
frequency machine vibration.
When "Vibration suppression control 1 tuning mode selection" is set to "Automatic
setting (_ _ _ 1)" in [Pr. PB02], this parameter will be set automatically.
When "Manual setting (_ _ _ 2)" is selected, the setting written to the parameter is
used. The setting range of this parameter varies, depending on the value in [Pr.
PB07]. If a value out of the range is set, the vibration suppression control will be
disabled. Refer to section 7.1.5 for details.
Setting range: 0.1 to 300.0
100.0
[Hz]
PB20
VRF12
Vibration
suppression
control 1 -
Resonance
frequency
Set the resonance frequency for vibration suppression control 1 to suppress low-
frequency machine vibration.
When "Vibration suppression control 1 tuning mode selection" is set to "Automatic
setting (_ _ _ 1)" in [Pr. PB02], this parameter will be set automatically.
When "Manual setting (_ _ _ 2)" is selected, the setting written to the parameter is
used. The setting range of this parameter varies, depending on the value in [Pr.
PB07]. If a value out of the range is set, the vibration suppression control will be
disabled. Refer to section 7.1.5 for details.
Setting range: 0.1 to 300.0
100.0
[Hz]
PB21
VRF13
Vibration
suppression
control 1 -
Vibration
frequency
damping
Set a damping of the vibration frequency for vibration suppression control 1 to
suppress low-frequency machine vibration.
When "Vibration suppression control 1 tuning mode selection" is set to "Automatic
setting (_ _ _ 1)" in [Pr. PB02], this parameter will be set automatically.
When "Manual setting (_ _ _ 2)" is selected, the setting written to the parameter is
used. Refer to section 7.1.5 for details.
Setting range: 0.00 to 0.30
0.00
PB22
VRF14
Vibration
suppression
control 1 -
Resonance
frequency
damping
Set a damping of the resonance frequency for vibration suppression control 1 to
suppress low-frequency machine vibration.
When "Vibration suppression control 1 tuning mode selection" is set to "Automatic
setting (_ _ _ 1)" in [Pr. PB02], this parameter will be set automatically.
When "Manual setting (_ _ _ 2)" is selected, the setting written to the parameter is
used. Refer to section 7.1.5 for details.
Setting range: 0.00 to 0.30
0.00
PB23
VFBF
Low-pass
filter selection
_ _ _ x Shaft resonance suppression filter selection
Select the shaft resonance suppression filter.
0: Automatic setting
1: Manual setting
2: Disabled
When "Machine resonance suppression filter 4 selection" is set to "Enabled (_ _ _
1)" in [Pr. PB49], the shaft resonance suppression filter is not available.
0h
_ _ x _ Low-pass filter selection
Select the low-pass filter.
0: Automatic setting
1: Manual setting
2: Disabled
0h
_ x _ _ For manufacturer setting
1h
x _ _ _
0h
PB24
*MVS
Slight
vibration
suppression
control
_ _ _ x Slight vibration suppression control selection
Select the slight vibration suppression control.
0: Disabled
1: Enabled
To enable the slight vibration suppression control, select "Manual mode (_ _ _ 3)" of
"Gain adjustment mode selection" in [Pr. PA08]. Slight vibration suppression control
cannot be used in the speed control mode.
0h
_ _ x _ For manufacturer setting
0h
_ x _ _
0h
x _ _ _
0h
Summary of Contents for MR-JE-_A
Page 9: ...A 8 MEMO ...
Page 15: ...6 MEMO ...
Page 29: ...1 FUNCTIONS AND CONFIGURATION 1 14 MEMO ...
Page 139: ...4 STARTUP 4 38 MEMO ...
Page 187: ...5 PARAMETERS 5 48 MEMO ...
Page 221: ...6 NORMAL GAIN ADJUSTMENT 6 34 MEMO ...
Page 259: ...8 TROUBLESHOOTING 8 8 MEMO ...
Page 265: ...9 DIMENSIONS 9 6 MEMO ...
Page 273: ...10 CHARACTERISTICS 10 8 MEMO ...
Page 339: ...12 COMMUNICATION FUNCTION MITSUBISHI ELECTRIC GENERAL PURPOSE AC SERVO PROTOCOL 12 34 MEMO ...