7. SPECIAL ADJUSTMENT FUNCTIONS
7 - 6
(3) Adaptive tuning mode procedure
No
No
Yes
Yes
No
Yes
Execute or re-execute adaptive
tuning in the high accuracy mode.
(Set [Pr. PB01] to "1 _ _ 1".)
In the standard mode
In the high accuracy mode
Execute or re-execute adaptive
tuning in the standard mode.
(Set [Pr. PB01] to "0 _ _ 1".)
Tuning ends automatically after the
predetermined period of time.
([Pr. PB01] will be "_ _ _ 2" or "_ _ _
0".)
Adaptive tuning
Operation
Is the target response
reached?
Decrease the response until vibration
or unusual noise is resolved.
End
Yes
No
No
Yes
Increase the response setting.
Has vibration or unusual
noise occurred?
Has vibration or unusual
noise been resolved?
Using the machine analyzer, set the
filter manually.
Yes
No
Factor
The response has increased to the machine limit.
The machine is too complicated to provide the
optimum filter.
If assumption fails after tuning is executed at a large vibration or
oscillation, decrease the response setting temporarily down to
the vibration level and execute again.
Summary of Contents for MR-JE-_A
Page 9: ...A 8 MEMO ...
Page 15: ...6 MEMO ...
Page 29: ...1 FUNCTIONS AND CONFIGURATION 1 14 MEMO ...
Page 139: ...4 STARTUP 4 38 MEMO ...
Page 187: ...5 PARAMETERS 5 48 MEMO ...
Page 221: ...6 NORMAL GAIN ADJUSTMENT 6 34 MEMO ...
Page 259: ...8 TROUBLESHOOTING 8 8 MEMO ...
Page 265: ...9 DIMENSIONS 9 6 MEMO ...
Page 273: ...10 CHARACTERISTICS 10 8 MEMO ...
Page 339: ...12 COMMUNICATION FUNCTION MITSUBISHI ELECTRIC GENERAL PURPOSE AC SERVO PROTOCOL 12 34 MEMO ...