3. SIGNALS AND WIRING
3 - 18
3.3.3 Wiring CNP1 and CNP2
POINT
For the wire sizes used for wiring, refer to section 11.5.
When wiring, remove the power connectors from the servo amplifier.
Insert only one wire or ferrule to each wire insertion hole.
To wire to CNP1 and CNP2, use servo amplifier power connectors packed with the amplifier or optional
connectors (refer to section 11.1.1).
(1) Connector
(a) MR-JE-10A to MR-JE-100A
CNP1
Servo amplifier
Table 3.1 Connector and applicable wire
Connector
Receptacle
assembly
Applicable wire
Stripped
length [mm]
Open tool
Manu-
facturer
Size Insulator
OD
CNP1
09JFAT-SAXGDK-H5.0
AWG 18 to 14
3.9 mm or shorter
9
J-FAT-OT (N)
or
J-FAT-OT
JST
(b) MR-JE-200A/MR-JE-300A
CNP1
CNP2
Servo amplifier
Table 3.2 Connector and applicable wire
Connector
Receptacle
assembly
Applicable wire
Stripped
length [mm]
Open tool
Manu-
facturer
Size Insulator
OD
CNP1 06(7-4)JFAT-SAXGFK-XL
AWG 16 to 10
4.7 mm or shorter
11.5
J-FAT-OT-EXL
JST
CNP2 03JFAT-SAXGFK-XL
Summary of Contents for MR-JE-_A