7. OBJECT DICTIONARY
7 - 23
7.4 Object dictionary details (1000 series)
POINT
This section describes the objects of the 1000 series. Refer to section 7.3 for
details on the objects that are not listed here.
7.4.1 Manufacturer Device Name (1008h)
(1) Object list
Index Sub
Index
Name
Data
Type Access
No. of points/No.
of Registers
Continuous read/
continuous write
1008h
0
Manufacturer Device Name
VS
ro
16
Impossible
The model name of the servo amplifier can be read.
This is available with servo amplifiers with software version A4 or later.
(2) Usage
Use this object to read the model name of the servo amplifier (ASCII: 16 characters).
Fill with spaces (20h) if the model name is less than 32 characters.
As an example, for MR-JE-20C it will be as follows.
Byte
0
1
2
3
4
5
6
7
8
9 to 32
Characters M
R
-
J
E
-
2
0
C
(Space)
7.4.2 Manufacturer Hardware Version (1009h)
(1) Object list
Index Sub
Index
Name
Data
Type Access
No. of points/
No. of Registers
Continuous read/
continuous write
1009h
0
Manufacturer Hardware Version
VS
ro
1
Impossible
The hardware version of the network module can be read.
Can be used with servo amplifiers with software version A4 or later.
(2) Usage
Use this object to read the hardware version (ASCII: 2 characters) of the network module.
Fill with spaces (20h) if the model name is less than 2 characters.
As an example, if the hardware version is A, it will be as follows.
Byte
0
1
Characters A
(Space)