7. OBJECT DICTIONARY
7 - 50
(b) Measuring the multi axis waveform data
1) After connecting the servo amplifier and MR Configurator2 with a USB cable, click "Start" to start
measuring the waveform in the trigger mode.
2) Perform the operation 1) on all other target axes (servo amplifiers) to start measuring the
waveforms.
Wait state of
trigger conditions
fulfillment
Reception of
"Start" command
Personal computer
USB
communication
The axes to be
measured 1
"Start" command
Servo amplifier
The axes to be
measured 2
Servo amplifier
The axes to be
measured 3
Servo amplifier
The axes to be
measured N
Servo amplifier
Start of measuring the waveforms at all the axes to be
measured by connecting servo amplifiers one by one.
3) Set Select behavior of broadcast message (2D98h) to "0 (Broadcast command enabled)"
Refer to chapter 4 for the broadcast setting.
At the timing when the graph data is required, set "1 (Setup software graph trigger on)" for Setup
S/W graph trigger (2D99h) on the broadcast communication of Modbus RTU.
Programmable
controller
Communication
Start of data
buffering
"Setup S/W graph
trigger" on
Transmission of "Setup software graph trigger on"
The axes to be
measured 1
Servo amplifier
The axes to be
measured 2
Servo amplifier
The axes to be
measured 3
Servo amplifier
The axes to be
measured N
Servo amplifier