7. OBJECT DICTIONARY
7 - 55
7.6.2 Quick stop option code (605Ah)
Index Sub
Index
Name
Data
Type Access
No. of Points/
No. of Registers
Continuous read/
continuous write
605Ah
0
Quick stop option code
I16
rw
1
Impossible
The operation method of deceleration to a stop can be specified. The following table shows the supported
methods and the operations.
Setting
value
Description
1
For manufacturer setting
2
In the profile mode (pp/pv), point table mode (pt), indexer mode (idx), Jog mode (jg), and homing mode (hm), the servo
motor decelerates to a stop with Quick stop deceleration (6085h), and the staus shift to the Switch On Disabled. The new
setting of Quick stop deceleration is reflected at all times.
In the profile torque mode (tq), the status immediately shift to the Switch On Disabled state and the servo motor stops with
the dynamic brake.
3
For manufacturer setting
4
5
6
7
8
7.6.3 Halt option code (605Dh)
(1) Object list
Index Sub
Index
Name
Data
Type Access
No. of Points/
No. of Registers
Continuous read/
continuous write
605Dh
0
Halt option code
I16
rw
1
Impossible
The following table shows descriptions of Halt option code (605Dh).
Setting
value
Description
1
The description varies depending on the control mode.
Refer to the following table.
2
For manufacturer setting
3
4