7. OBJECT DICTIONARY
7 - 56
The following shows the case where Halt Bit (Bit 8 of Controlword (6040h)) is set to "1" and "0", and the
reflective timing of the deceleration time setting in each control mode.
Control mode
Halt Bit is set to "1"
Halt Bit is set to "0"
Reflective timing of deceleration time
setting
Profile position mode (pp)
The servo motor decelerates
to a stop in accordance with
Profile deceleration (6084h).
The operation restarts after the
servo motor decelerates to a
stop.
The new setting of Profile
deceleration (6084h) is reflected
when New set-point (Bit 4 of
Controlword (6040h)) is set to "1".
Profile velocity mode (pv)
The servo motor decelerates
to a stop in accordance with
Profile deceleration (6084h).
The operation restarts after the
servo motor decelerates to a
stop.
The change of Profile deceleration
(6084h) is reflected at all times.
Profile torque mode (tq)
Torque demand value
(6074h) becomes "0" with the
amount of torque change set
in Torque slope (6087h)
regardless of Halt option code
(605Dh).
The operation restarts after
Torque demand value (6074h)
becomes "0".
The new setting of Torque slope
(6087h) is reflected at all times.
Homing mode (hm)
When Halt Bit is set to "1", the servo motor decelerates to a
stop with Homing acceleration (609Ah) and the status remain
as Operation Enabled (servo-on). Then, home position return is
restarted with the following procedure: (1) set Halt Bit to "0", (2)
reset Homing Operation Start (Bit 4 of Controlword (6040h)) to
"0", and (3) change Homing Operation Start (Bit 4 of
Controlword (6040h)) to "1".
The new setting of Homing
acceleration (609Ah) is reflected
when Homing Operation Start (Bit 4 of
Controlword (6040h)) is set to "1".
Point table mode (pt)
The servo motor decelerates
to a stop in accordance with
the deceleration time constant
set in Point table 001 to Point
table 255 (2801h to 28FFh).
The operation restarts
immediately.
The new setting is reflected when the
next operation starts.
Indexer mode (idx)
Halt Bit is disabled in the indexer mode.
Jog mode (jg)
The servo motor decelerates
to a stop in accordance with
Profile deceleration (6084h).
The operation restarts
immediately.
The new setting of Profile
deceleration (6084h) is reflected
when New set-point (Bit 4 of
Controlword (6040h)) is set to "1".
Summary of Contents for MR-JE-C Series
Page 9: ...A 8 MEMO ...
Page 13: ...4 MEMO ...
Page 33: ...2 CC Link IE Field Network Basic SLMP 2 16 MEMO ...
Page 73: ...5 PARAMETERS 5 14 MEMO ...
Page 79: ...6 MANUFACTURER FUNCTIONS 6 6 MEMO ...
Page 143: ...MEMO ...