5. PARAMETERS
5 - 1
5. PARAMETERS
CAUTION
Never make a drastic adjustment or change to the parameter values as doing so
will make the operation unstable.
Do not change the parameter settings as described below. Doing so may cause
an unexpected condition, such as failing to start up the servo amplifier.
Changing the values of the parameters for manufacturer setting
Setting a value out of the range
Changing the fixed values in the digits of a parameter
When you write parameters with the controller, make sure that the identification
No. of the servo amplifier is set correctly. Otherwise, the parameter settings of
another identification No. may be written, possibly causing the servo amplifier to
be an unexpected condition.
5.1 Parameter list
POINT
To enable a parameter whose symbol is preceded by *, cycle the power after
setting it. However, the time will be longer depending on a setting value of [Pr.
PF25 Instantaneous power failure tough drive - Detection time] when
"instantaneous power failure tough drive selection" is enabled in [Pr. PA20].
5.1.1 Extension setting parameters ([Pr. PC_ _ ])
POINT
The following parameters can be used only for Modbus RTU communication.
[Pr. PC70 Modbus RTU communication station number setting]
[Pr. PC71 Function selection C-F]
[Pr. PC72 Function selection C-G]
No.
Symbol
Name
Initial
value
Unit
PC01
STA
JOG operation acceleration time constant
0
[ms]
Acceleration time constant 1
0
[ms]
PC02
STB
JOG operation deceleration time constant
0
[ms]
Deceleration time constant 1
0
[ms]
PC03
STC
S-pattern acceleration/deceleration time constant
0
[ms]
PC04
TQC
Torque command time constant
0
[ms]
PC05
SC1
Automatic operation speed 1
100.00
[r/min]
PC06
SC2
Automatic operation speed 2
500.00
[r/min]
PC07
SC3
Manual operation speed 1
1000.00
[r/min]
PC08
SC4
Manual operation speed 2
200.00
[r/min]
PC09
SC5
Internal speed command 5
300.00
[r/min]
Internal speed limit 5
PC10
SC6
Internal speed command 6
500.00
[r/min]
Internal speed limit 6
PC11
SC7
Internal speed command 7
800.00
[r/min]
Internal speed limit 7
PC12
VCM
Analog speed command - Maximum speed
0.00
[r/min]
Analog speed limit - Maximum speed
Summary of Contents for MR-JE-C Series
Page 9: ...A 8 MEMO ...
Page 13: ...4 MEMO ...
Page 33: ...2 CC Link IE Field Network Basic SLMP 2 16 MEMO ...
Page 73: ...5 PARAMETERS 5 14 MEMO ...
Page 79: ...6 MANUFACTURER FUNCTIONS 6 6 MEMO ...
Page 143: ...MEMO ...