81
System control (for Mr.Slim)
1. Remote Controller (Standerd) Operation
1-1. Wired Remote Controller
(OC: Outdoor unit IC: Indoor unit R: Remote controller (for wireless type: optical receiver adapter)
Slim Air Conditioners
System
Standard 1:1
Simultaneous Twin
Simultaneous Triple
Simultaneous Quad
System diagram (Wired remote controller)
Outdoor unit OC
Indoor unit IC
Wired remote
controller R
* Numbers given in ( ) apply when power is supplied to the indoor and outdoor units separately.
<Reference>
1) If simultaneous twin or triple or quad, connect the remote controller to any one of the indoor units. All functions of the indoor
unit can be controlled even if different models (different types) are mixed.
2) Do not use crossover wiring among indoor units with simultaneous twin, triple, quad units. (Prohibited item.)
3) Electrical wiring diagram
1-2. Wired Remote Controller or Wireless Remote Controller Receiver Built into Indoor Unit
[Floor type (wired remote controller)/-way ceiling cassette type, ceiling suspended type, wall mounted type (wireless remote
controller)]
Slim Air Conditioners
System
Standard 1:1
Simultaneous Twin
Simultaneous Triple
Simultaneous Quad
System diagram (Wired remote controller or wireless remotecontroller receiver)
Outdoor unit OC
Indoor unit IC
Wired remote con-
troller or reciever R
* Numbers given in ( ) apply when power is supplied to the indoor and outdoor units separately.
<Reference>
1) If simultaneous twin or triple or quad, connect the remote controller to any one of the indoor units. All functions of the indoor
unit For systems containing built-in wired remote controllers (or built-in wireless receiver adapters) and consisting of simul-
taneous twin, triple and quad units only, the installed remote controllers (or receiver adapters) must be connected without
changing any settings. If the system consists of different models, keep only one of the remote controllers built into the indoor
units, or remove all the remote controller cables and connect them to other models according to 1-1.
2) Use the wired remote controllers without setting them as the main and sub controllers.
Indoor/Outdoor
connection
cable
Remote
controller
cable
OC
IC-1
R
3
2
OC
IC-1
R
IC-2
3
2
3
OC
3(2)
3(2)
2
IC-1
IC-2
IC-3
R
3(2)
L
1
L
2
L
3
N
OC
S1
S2
S3
S1
S2
S3
IC
1
2
1
2
R
(No polarity)
Outdoor unit
Indoor unit
Remote controller
Power
source
wiring
(Polarity)
OC
3(2) 3(2)
2
IC-1
IC-2
IC-3
IC-4
R
3(2)
3(2)
OC
3(2)
IC
R
Indoor/outdoor
connection cable
OC
3(2)
3(2)
IC-1
IC-2
R-1
R-2
OC
3(2) 3(2)
IC-1
IC-2
IC-3
R-1
R-2
R-3
3(2)
OC
3(2) 3(2)
IC-1
IC-2
IC-3
IC-4
R-1
R-2
R-3
R-4
3(2)
3(2)