3-minute drain
pump ON
Operation mode
Cooling mode
Cooling display
Prohibition
Cooling operation
Refer to 2-(1)
Heating mode
Heating display
Prohibition
Heating operation
Refer to 2-(2)
Dry mode
Dry display
Prohibition
Dry operation
Refer to 2-(3)
Fan mode
Fan display
Fan operations
Start
Breaker
turned on
Operation SW
turned on
1. Protection function
self-holding
cancelled.
2. Indoor unit LEV fully
closed.
Remove controller
display extinguished
Auxiliary heater
ON
FAN stop
Drain pump
ON
1. Auxiliary
heater OFF
2. Fan low speed
for 1 minute
Prohibition “Remote
controller blinking”
Operation command to outdoor unit (to 2 )
Error mode
Error stop
Error display
Protection func-
tion self-holding
Error command
to outdoor unit
Indoor unit LEV
fully closed
Normal operation
Trouble observed
Stop
YES
NO
NO
NO
YES
YES
NO
YES
NO
YES
YES
NO
Note:
❉
3
YES
NO
Note:
❉
3
YES
NO
Note:
❉
3
Note:
❉
2
Note:
❉
1
Notes :
❉
1 Indoor unit LEV fully closed : Opening 41.
❉
2 The error mode includes that of indoor units and outdoor units. At indoor side error (excluding water leak), the indoor unit in
trouble only will be stopped in emergency, while at outdoor side error, all indoor units connected will be stopped.
❉
3 Prohibition status is observed when the set cooling/heating mode is different from that of the outdoor unit.
1
From outdoor unit
- 76 -
[3] Operation Flow Chart
1. Flow to determine the mode
(1) Indoor unit (cooling, heating, dry, fan mode)