background image

10

A1 A2

9

Carefully remove front panel 

by disconnecting the control 

cable from beneath the unit’s

main control box.

1

The blanking plate and gasket 

can be removed using a narrow 

flat bladed screwdriver.

Dispose

Check before starting installation 

that no water is in the tank.

2

Diagonally locate the thermostat pockets on upper 
right and bottom left with termini on the upper left 
and bottom right sides as shown.
Secure tightly with the nut to prevent water leakage. 
(Recommended torque = 10 N•m)

3

Reinstate plastic tab cover over 
the connectors then insert the 
thermostat rod into the upper 
right hand pocket.
The terminals on the white 
plastic head should be positioned 
at the bottom as shown.

4

Assemble     and     securely.

5

 Screw positions

6

Place the terminal 
blocks so that the 
orientations of the 
labels are correct.

7

Align the centre lines 

and

 as shown.

Align the centre 
lines

 and 

as shown.

Connector CNIH

8

11

Do not insert the lead wires 

 and 

 into the

opening that the main controller wires or the 
wireless receiver wires use.


12

13

Run the lead wire through 
the slit on the water-proof 
cover provided and seal 
each terminal screw.

14

Place the band on the joint surface of the 
DHW tank.
Secure the water-proof cover around the 
cylinder boss using the band provided.

15

Dip Switch
1-4 OFF

ON

(without immersion heater

with immersion heater)

17

18

Carefully reinstate control cable 

connection before reinstating 

and securing the front panel.

16

For details about wiring to power supply and 
circuit breaker, refer to the installation 
manual for the cylinder unit.
Fill tank with water and ensure that no water 
leaks around the periphery of the immersion 
heater.

BH79D212H02

Reviews: