background image

– 2 –

 WARNING

 CAUTION

 WARNING

 CAUTION

 WARNING

                                                                                 

 CAUTION

 

 

Precautions during installation

 

Precautions during wiring

 

Precautions for moving or repairing the controller

 

Additional precautions

Do not install the controller where there is a risk of leaking flammable 
gas. If flammable gas accumulates around the controller, it may ignite 
and cause a fire or explosion.

Properly dispose of the packing materials. Plastic bags pose 
suffocation hazard to children.

Take appropriate safety measures against earthquakes to prevent 
the controller from causing injury.

To prevent injury, install the controller on a flat surface strong 
enough to support its weight.

To reduce the risk of shorting, current leakage, electric shock, 
malfunctions, smoke, or fire, do not install the controller in a place 
exposed to water or in a condensing environment.

Controller must be installed by qualified personnel according to the
instructions detailed in the Installation Manual.
Improper installation may result in electric shock or fire.

When attaching the cover and the top casing to the bottom casing, 
push it until it they click into place. If they are not properly locked 
into place, they may fall, causing personal injury, controller 
damage, or malfunctions.

To reduce the risk of damage to the controller, malfunctions, smoke, or 
fire, do not connect the power cable to the signal terminal block.

Properly secure the cables in place and provide adequate slack in 
the cables so as not to stress the terminals.Improperly connected 
cables may break, overheat, and cause smoke or fire.

To reduce the risk of injury or electric shock, switch off the main 
power before performing electrical work.

All electric work must be performed by a qualified electrician 
according to the local regulations, standards, and the instructions 
detailed in the Installation Manual. Capacity shortage to the power 
supply circuit or improper installation may result in malfunction, 
electric shock, smoke, or fire.

To reduce the risk of current leakage, overheating, smoke, or fire, 
use properly rated cables with adequate current carrying capacity.

To reduce the risk of electric shock, shorting, or malfunctions, keep 
wire pieces and sheath shavings out of the terminal block.

To reduce the risk of shorting, current leakage, electric shock, or 
malfunctions, keep the cables out of contact with controller edges.

To reduce the risk of electric shock, malfunctions, or fire, seal the 
gap between the cables and cable access holes with putty.

The controller should be repaired or moved only by qualified 
personnel. Do not disassemble or modify the controller.
Improper installation or repair may cause injury, electric shock, or fire.

To reduce the risk of shorting, electric shock, fire, or malfunction, 
do not touch the circuit board with tools or with your hands, and do 
not allow dust to accumulate on the circuit board.

To avoid damage to the controller, use appropriate tools to install, 
inspect, or repair the controller.

This controller is designed for exclusive use with the Building 
Management System by Mitsubishi Electric. The use of this controller 
for with other systems or for other purposes may cause malfunctions.

Take appropriate measures against electrical noise interference 
when installing the air conditioners in hospitals or facilities with 
radio communication capabilities. Inverter, high-frequency medical, 
or wireless communication equipment as well as power generators 
may cause the air conditioning system to malfunction. Air 
conditioning system may also adversely affect the operation of 
these types of equipment by creating electrical noise.

To avoid malfunctions, do not bundle power cables and signal 
cables together, or place them in the same metallic conduit.

To prevent malfunctions, do not remove the protective film or the 
circuit board from the casing. 

To avoid damage to the controller, do not overtighten the screws. 

Use a flat-head screwdriver with a blade width of 4-7 mm (5/32-9/
32 inch). The use of a screwdriver with a narrower or wider blade 
tip may damage the controller casing.

To prevent damage to the controller casing, do not force the driver 
to turn with its tip inserted in the slot. 

To avoid discoloration, do not use benzene, thinner, or chemical 
rag to clean the controller. To clean the controller, wipe with a soft 
cloth soaked in water with mild detergent, wipe off the detergent 
with a wet cloth, and wipe off water with a dry cloth. 

WT06695X01_1_GB_A5.fm  Page 2  Tuesday, August 7, 2012  3:29 PM

Summary of Contents for PAR-31MAA

Page 1: ...nel Do not install the unit in a place where large amounts of oil steam organic solvents or corrosive gases such as sulfuric gas are present or where acidic alkaline solutions or sprays are used frequently These substances can compromise the performance of the unit or cause certain components of the unit to corrode which can result in electric shock malfunctions smoke or fire To reduce the risk of...

Page 2: ...risk of electric shock shorting or malfunctions keep wire pieces and sheath shavings out of the terminal block To reduce the risk of shorting current leakage electric shock or malfunctions keep the cables out of contact with controller edges To reduce the risk of electric shock malfunctions or fire seal the gap between the cables and cable access holes with putty The controller should be repaired ...

Page 3: ...he box WARNING The CD ROM that is supplied with the Remote Controller can only be played on a CD drive or a DVD drive Do not attempt to play this CD ROM on an audio CD player as this may damage your ears and or speakers 4 The front cover 1 is already installed on the top case 2 at factory shipment 5 Remote controller cable is not included To avoid damage to the controller provide protection agains...

Page 4: ... the remote controller where no wires are routed around the temperature sensor on the controller If wires are routed the sensor cannot measure accurate indoor temperature Parts name Qty Notes Double switch box 1 Not required for direct wall installation Thin metal conduit Necessary Lock nut and bushing Necessary Cable cover Necessary Required for routing remote controller cable along a wall Putty ...

Page 5: ...troller cable access hole at the connection of switch box and conduit tube with putty 3 Prepare the bottom case of the remote controller Direct wall installation Seal the hole through which the cable is threaded with putty To reduce the risk of electric shock malfunctions or fire seal the gap between the cables and cable access holes with putty Wall Conduit tube Locknut Switch box Seal the gap wit...

Page 6: ...n the cover indicated with the shaded area in the right figure with a knife or a nipper Thread the cable from the groove behind the bottom case through this access hole Installation using a switch box Direct wall installation Seal the cable access hole with putty Double switch box Roundhead cross slot screws Remote controller cable Wood screw Remote controller cable Thread the cable through the gr...

Page 7: ...bottom of the remote controller and move it in the direction of the arrow as shown in the figure at right Hold the cables in place with clamps to prevent undue force from being applied to the terminal block and causing cable breakage Important Clamp Insert the wire When attaching the cover and the top casing to the bottom casing push it until it they click into place If they are not properly locke...

Page 8: ...the protective sheet on the operation interface prior to use 3 Installing the cover and top case Two mounting tabs are at the top of the top case Hook those two tabs onto the bottom case and click the top case into place Install the cover on the top case in the same way as with the top case Check that the top case is securely installed and not lifted Note When temperature changes rapidly the tempe...

Page 9: ... Cursor Page Main menu Vane Louver Vent Lossnay High power Timer Weekly timer OU silent mode Page Cursor Move the cursor to the desired function with the F1 and F2 buttons and press the SELECT button to go to the next page Password may be required The function of the MENU SELECT and RETURN buttons will appear on the setting screens Button function guide will appear at the bottom of the screens Pre...

Page 10: ...creen will be displayed Refer to section 11 8 Select a desired language The system will not start up without language selection Some models of City Multi cannot have more than one remote controller connected Refer to relevant documents e g catalogs for usage compatibility Normal start up indicating the percentage of process completion Notes When connecting two remote controllers be sure to designa...

Page 11: ...ange to bring up the clock display setting screen Use the F1 through F4 buttons to select Yes display or No non display and its format for the Main display Save the settings with the SELECT button The factory settings are Yes display and 24 h format Clock display Yes Time is displayed on the Main display No Time is not displayed on the Main display Display format 24 hour format 12 hour format AM P...

Page 12: ...and set each number 0 through 9 with the F3 or F4 button 2 Press the SELECT button Note The initial administrator password is 0000 Change the default password as necessary to prevent unauthorized access Have the password available for those who need it Note If you forget your administrator password you can initialize the password to the default password 0000 by pressing and holding the F1 and F2 b...

Page 13: ... following settings can be made from the Maintenance Information screen Registering model names and serial numbers Enter the model names and serial numbers of outdoor and indoor units The information entered will appear on the Error information screen Model names can have up to 18 characters and the serial numbers can have up to 8 characters Registering dealer information Enter phone number of a d...

Page 14: ... 1 2 3 4 or All for the Unit number These settings apply to each indoor unit If 1 2 3 or 4 is set for the Unit number the settings apply only to the specified indoor unit regardless of the number of connected indoor units one through four units If ALL is set for the Unit number the settings apply to all the connected indoor units regardless of the number of connected indoor units one through four ...

Page 15: ... 2 Other options in the Check menu Mr Slim only The following options are also available on the Mr Slim units in the Check menu Deleting the error history To delete the error history press the F4 button Delete on the screen that shows error history A confirmation screen will appear asking if you want to delete the error history Press the F4 button OK to delete the history Refrigerant volume check ...

Page 16: ...Resetting the error history 1 Press the F4 button Reset on the screen that shows the error history A confirmation screen will appear asking if you want to delete the error history 2 Press the F4 button OK to delete the error history If deletion fails Request rejected will appear and Unit not exist will appear if no indoor units that are correspond to the entered address are found Procedures 1 Sele...

Reviews: