35
4
F1
F2
F3
F4
Temp. range
Temp. range
Select:
Cursor
Temp.
Main menu:
Temp. range No /
Yes
Cool
·Dry
Heat
Auto
Temp. range No /
Yes
Cool
·Dry
Heat
Auto
Changes saved
-
-
-
-
-
-
Change the settings with the F3 or F4 button.
•
Temp. range:
No (unrestricted) or
Yes (restricted)
• Cool•Dry:
Upper and lower limit temperature
(1ºC increments)
•
Heat: Upper and lower limit temperature
(1ºC increments)
•
Auto: Upper and lower limit temperature
(1ºC increments)
Press the SELECT button to save the settings.
A confirmation screen will appear.
Cool
Room
Auto
Set temp.
Mode
Temp.
Fan
Fri
will appear on the Main display in the Full
mode when the temperature range is restricted.
Temperature setting ranges
Mode
Lower limit
Upper limit
Cool
•
Dry
19 ~ 30ºC
(67 ~ 87ºF)
30 ~ 19ºC
(87 ~ 67ºF)
Heat
17 ~ 28ºC
(63 ~ 83ºF)
28 ~ 17ºC
(83 ~ 63ºF)
Auto
19 ~ 28ºC
(67 ~ 83ºF)
28 ~ 19ºC
(83 ~ 67ºF)
* The settable range varies depending on the connected unit.
*1 Temperature ranges for the Cool, Dry, and Auto (dual set
point) modes can be set.
*2 Temperature ranges for the Heat and Auto (dual set point)
modes can be set.
*3 Temperature ranges for the Heat, Cool, and Dry modes
must meet the conditions below:
•
Upper limit for cooling - upper limit for heating ≥ Minimum
temperature difference (varies with indoor unit model)
•
Lower limit for cooling - lower limit for heating ≥ Minimum
temperature difference (varies with indoor unit model)
*4 Temperature range for the Auto (single set point) mode can
be set.
Navigating through the screens
•
To go back to the Main menu .......... MENU button
•
To return to the previous screen ...... RETURN button
*1
*3
*2
*3
*4