Function Selection

This setting is available only for Mr. Slim model. CITY MULTI model can be set by dip switch of indoor/outdoor
control circuit board. Refer to technical data of CITY MULTI model to set dip switch.

Each function can be set according to necessity using the remote controller.
The setting of function for each unit can only be done by the remote controller.
Select function available from the Table3. Function selection using wireless remote controller 
is available only for refrigerant system with wireless function. Refrigerant address cannot 
be specified by the wireless remote controller.
The article below describes how to set “LOSSNAY connectivity” into “supported
(indoor unit is not equipped with outdoor-air intake)” in Table 3 as an example.

 Go to the function select mode

               Press the          button 

 twice continuously. 

               (Start this operation from the status of remote controller display turned off.)

CHECK

is lighted and “00” blinks.

               Press the temp      button 

 once to set “50”. Direct the wireless remote 

               controller toward the receiver of the indoor unit and press the         button 

.

 Setting the unit number

               Press the temp          button 

 and 

 to set the unit number “00”. Direct 

               the wireless remote controller toward the receiver of the indoor unit and 
               press the         button 

.

 Selecting a mode

               Enter 03 to change the LOSSNAY connectivity setting using the      

 and

 buttons. Direct the wireless remote controller toward the receiver 

               of the indoor unit and press the          button 

.

               Current setting number:                         1=1 beep (1 second)
                                                                              2=2 beeps (1 second each)
                                                                              3=3 beeps (1 second each)

 If a mode number that can not be recognized by the unit is entered, 

             3 beeps (3 beeps of 0.4 seconds duration)will be heard. 
             Reenter the mode number selecting.

 If the signal was not received by the sensor or an error occurred during 

             transmission, you will not hear a beep or a “double beep” may be heard.
             Press the          button again.

 Selecting the setting number

               Use the

 and

 buttons to change the LOSSNAY connectivity setting

               to 02. Direct the wireless remote controller toward the sensor of the indoor
               unit and press the          button 

.

ĺ$WWKLVWLPHFXUUHQWVHWWLQJQXPEHUIRUVHOHFWHGPRGHQXPEHUZLOOEHRXWSXW

                  by the interrupted buzzer sounds and the blinks of operation indicator.

2XWSXWVHWWLQJQXPEHU ĺEHHSEHHSVHFRQGVHFRQGî
ĺEHHSEHHSVHFRQGVHFRQGî
ĺEHHSEHHSVHFRQGVHFRQGî

 If a setting number that can not be recognized by the unit is entered, 3 beeps

             (3 beeps of 0.4 seconds duration) will be heard (unit will beep only).
             Reenter the setting number selecting.

 If the signal was not received by the sensor or an error occurred during

             transmission, you will not hear a beep or a “double beep” may be heard.
             Press the          button again.

 If the number that can not be set is input, the former setting number will be set.

 To select multiple functions continuously

                Repeat steps 

 and 

 to change multipul function settings continuously.

 Complete function selection

                Direct the wireless remote controller toward the sensor of the indoor unit
                and press the 

 button 

.

CHECK

h

min

h

h

h

h

NOTE : Whenever changes are made to the function settings after construction or
             maintenance, be sure to record the added functions with an “

ż

”, in the

             “Check” column provided on the chart.

CHECK

CHECK

CHECK

CHECK

ON/OFF

  TEMP

FAN

VANE

TEST RUN

AUTO STOP

AUTO START

h

min

LOUVER

MODE

CHECK

RESET

SET

CLOCK

CHECK

5

Wireless Remote Controller Kit

for Ceiling Suspended models

PAR-SL94B-E

Summary of Contents for PAR-SL94B-E

Page 1: ...systems per group One or more wireless light receivers must be installed for each refrigerant system Number of units controlled Adapter wiring 9 wire cord standard accessory with connector is connected to the connector CN90 on the indoor unit control board Light receiver range 7m or less at within 45 degrees to the front of receiver the range varies with conditions Operating conditions Temperature...

Page 2: ...the grille Remove the screw holding the side panel and then slide the side panel forward to remove it Side panel Slide forward Catach retaining the intake grille Remove the screw holding the side panel Removing the existing brand label case Remove the brand label case name plate with MITSUBISHI ELECTRIC from the bottom right of the unit If it is difficult to remove the case use a flat blade screwd...

Page 3: ...sert the remote control into the holder Push the remote control against the wall Removing remote control Ɣ Pull the top of remote control forward NOTE The remote signal will reach the receiver over a distance of approx 7m in a straight line and approx 45 left or right If the infrared receiver is affected by fluorescent light especially inverter type it may not be able to receive the signal Take th...

Page 4: ...O STOP AUTO START h min RESET SET CLOCK MODEL SELECT The positions of the connectors may be different according to the model Please refer to the wiring diagram to confirm the positions of the connectors Test Run Measure an impedance between the power supply terminal block on the outdoor unit and the ground with a 500V Megger and check that it is equal to or greater than 1 0 M Turn on the main powe...

Page 5: ...d by the unit is entered 3 beeps 3 beeps of 0 4 seconds duration will be heard Reenter the mode number selecting If the signal was not received by the sensor or an error occurred during transmission you will not hear a beep or a double beep may be heard Press the button again Selecting the setting number Use the and buttons to change the LOSSNAY connectivity setting to 02 Direct the wireless remot...

Page 6: ...he function that can be set for the indoor unit Table 4 Itemized functions of the entire refrigerant system select unit number 00 Mode Settings Not available Available Approximately 4 minutes wait period after power is restored Indoor unit operating average Set by indoor unit s remote controller Remote controller s internal sensor Not supported Supported indoor unit is not equipped with outdoor ai...

Page 7: ...p Beep Beep Beep Off Approx 2 5 sec On 0 5 sec On 0 5 sec On 0 5 sec On 0 5 sec Off Approx 2 5 sec On 0 5 sec On 0 5 sec Repeated Number of blinks beeps in pattern indicates the check code in the following table i e n 5 for P5 Number of blinks beeps in pattern indicates the check code in the following table nth 1st 2nd 3rd 1st 2nd Self check starts Start signal received Beeper sounds Ɣ Refer to th...

Page 8: ...U7 U9 UH Others Other errors Refer to the technical manual for the outdoor unit For details check the LED display of the outdoor controller board Compressor overcurrent interruption On wireless remote controller The continuous buzzer sounds from receiving section of indoor unit Blink of operation lamp On wired remote controller Check code display in the LCD Wired remote controller Check code CITY ...