OUTLET
L E D 1
L E D 2
L E D 3
DUCT
INLET
DUCT
50Hz
3N~PE
POWER SUPPLY
380/400/415V
(FIELD SUPPLY)
PEH-RP8,10MYA:15A
CIRCUIT BREAKER
TO OUTDOOR
CONNECTING
(POLER)
POWER
3N~
380/400/415V
REMOTE CONTROLLER
BOARD
INDOO
CONTROLLER
POWER BOARD
INDOO
OUTDOOR UNIT
4 3 2 1
ON
ON
OFF
OFF
4
BLACK
WHITE
RED
1
3
2
C12
C0
CN20
SW
ON
OFF
CN
T B 6
T B 2
T B 5
T H 1
T H 2
T H 5
T B 4
5 2 F
5 1 F
DC
14V
X6
X5
X4
REMOTE CONTROLLER
SW
SW
1
2
1
2
1
2
1
2
1
2
1
2
3
1
1
2
3
4
5
6
7
8
9
1
2
3
4
1
2
1
2
1
2
2
3
3
3
1
CN2S
52F
MF1
CN02
CN01
ZNR
F1
LCD
L 1
L 2
L 3
N
PE
1
2
3
5
FAN
CN03
CN2
F B
C R
4 9 F
S 1
S 2
S 3
5 1 F
D C 14V
D C 14V
2 1
5 3 1
7 5 3 1
X4 X5 X6
1 2 3
CN21
CN29
CN41
CN3
CN2
CN2
CN9
PE
PE
PE
PE
PE
(50Pa)
(WHITE)
C02
(RED)
(150Pa)
PE
N
L1
T B 1
T B 3
L2
L3
S1
S2
S3
INDOOR UNIT [PEH-RP8, RP10MYA]
(1) Indoor Unit
• Models PEH-RP8MYA/RP10MYA
INDOOR UNIT
SYMBOL
NAME
MF1
FAN MOTOR (INDOOR)
51F
OVER CURRENT RELAY (INDOOR FAN MOTOR)
52F
CONTACTOR (INDOOR FAN MOTOR)
49F
INTERNAL THERMOSTAT (INDOOR FAN MOTOR)
TB2, 4, 5
TERMINAL BLOCK
TH1
ROOM TEMP. (0˚C/15k
Ω
, 25˚C/5.4k
Ω
)
TH2
THERMISTOR PIPE TEMP. (0˚C/15k
Ω
, 25˚C/5.4k
Ω
)
TH5
COND./EVA. TEMP. (0˚C/15k
Ω
, 25˚C/5.4k
Ω
)
F1
FUSE (4A 250VAC CLASS T)
ZNR
VARISTOR
X4-6
AUXILIARY RELAY (INDOOR CONTROLLER BOARD)
SW1
SWITCH (MODEL SELECTION)
SW2
SWITCH (CAPACITY CORD)
SWE
SWITCH (EMERGENCY OPERATION)
LED1
LED (POWER SUPPLY : INDOOR CONTROLLER BOARD)
LED2
LED (POWER SUPPLY : REMOTE CONTROLLER)
LED3
LED (TRANSMISSION : INDOOR-OUTDOOR)
CR
SURGE KILLER
CN03, CN21, 2D
CN20-22, 29, 32
CONNECTOR (INDOOR CONTROLLER BOARD)
CN41, 90, FAN
CN01, 02, 2S
CONNECTOR (INDOOR POWER BOARD)
C01, 02, 12
CONNECTOR (FAN MOTOR)
FB
FERRITE CORE
OUTDOOR UNIT
SYMBOL
NAME
TB3
TERMINAL BLOCK
REMOTE CONTROLLER
SYMBOL
NAME
TB6
TERMINAL BLOCK
Note:
1. The dotted lines show field wiring.
2. Color of earth wire is yellow and green twisting.
3. Specification subject to change without notice.
4. Indoor and outdoor connecting wires are made with
polarities, make sure matching wiring and terminal.
5. Emergency operation
If a trouble occurs with either the remote controller
or the indoor microcomputer and no other trouble
exisits, emergency operation for cooling or heating
can be performed by changing the setting of switch
(SWE) on the indoor controller board.
6. SW2 is shown PEH-RP10MYA setting.
In case of PEH-RP8MYA setting is shown as below.
Caution:
1. To protect fan motor from abnormal current,over
current relays is installed.
Therefore, do not change factory set value of over
current relays.
SW2
ON
OFF
4 3 2 1
PE
- 10 -
5
ELECTRICAL WIRING DIAGRAM