[16] - 1
[16] Program mode list
1.Wiper
Function Unit
Setting
range
Specification
Valid/invalid of the wiper output is switched.
- OF
The wiper is invalidated.
WIP
Wiper ON/OFF
ON
The wiper is validated.
W1
Wiper output (W) start time
(based on needle up
position)
ms
0 ~ 998
The output start time of the wiper output(W) can be set. Please
set referring to thread trimming timing chart.
W2
Wiper output (W) start time
ms
0 ~ 998
The output time of the wiper output(W) can be set. Please set
referring to thread trimming timing chart.
2.Slow start
Function Unit
Setting
range
Specification
Valid/invalid of the slow start is set.
- OF
The slow start is invalidated.
SL
Slow start ON/OFF
ON
The slow start is validated. Slow start will be applied to the start of
all stitching (when power is turned ON, during HALT, and during
jogging operation, etc.).
SLN
No. of slow start stitches
stitches
0 ~ 5
Number of stitches of the first sewing speed (slow start) can be
set.
S
Slow start speed
rpm
Maximum
speed range
The speed (slow start) of the first sewing can be set.
Sets effective/ineffective for super-slow start
- OF
Super slow start is set ineffective
SLS
Super slow start ON/OFF
ON
Super slow start is set effective. When (SL) setting is set
effective, the first stitch will start by super-slow speed.
SLP
Super slow start speed
rpm
25 ~ 100
Sets Super slow start speed.
3.Clamp
Function Unit
Setting
range
Specification
The repeat sewing operation is set.
- OF
The normal stitching operation is entered. (Repeat sewing
RP1-RP8 is invalidated.)
RPT
Repeat sewing ON/OFF
ON
The repeat sewing RP1-RP8 is validated.
RP1: The repeat sewing operation is set.
- OF
The normal stitching operation is entered. (Repeat sewing RP1 is
invalidated.)
RP1
Repeat sewing 1
ON
The repeat sewing RP1 is validated.(when the (RPT.) setting
[ON] only)
RP2: The repeat sewing operation is set.
- OF
The normal stitching operation is entered. (Repeat sewing RP2 is
invalidated.)
RP2
Repeat sewing 2
ON
The repeat sewing RP2 is validated.(when the (RPT.) setting
[ON] only)
RP3: The repeat sewing operation is set.
- OF
The normal stitching operation is entered. (Repeat sewing RP3 is
invalidated.)
RP3
Repeat sewing 3
ON
The repeat sewing RP3 is validated.(when the (RPT.) setting
[ON] only)
RP4: The repeat sewing operation is set.
- OF
The normal stitching operation is entered. (Repeat sewing RP4 is
invalidated.)
RP4
Repeat sewing 4
ON
The repeat sewing RP4 is validated.(when the (RPT.) setting
[ON] only)
RP5: The repeat sewing operation is set.
- OF
The normal stitching operation is entered. (Repeat sewing RP5 is
invalidated.)
RP5
Repeat sewing 5
ON
The repeat sewing RP5 is validated.(when the (RPT.) setting
[ON] only)