CODE
ERROR NAME
PROBABLE CAUSE
INSPECTION
E-058
X axis home positioning sensor error
-The connector of X-home sensor cable has not been firmly inserted.
-X-home sensor cable has been disconnected.
-Check the insertion of the connector.
-Check the X-axis home sensor signal by using IN/OUT setting mode.
E-059
Y axis home positioning sensor error
-The connector of Y-home sensor cable has not been firmly inserted.
-Y-home sensor cable has been disconnected.
-Check the insertion of the connector.
-Check the Y-axis home sensor signal by using IN/OUT setting mode.
E-060
PF axis home positioning sensor error
-The connector of PF-home sensor cable has not been firmly inserted.
-PF-home sensor cable has been disconnected.
-Check the insertion of the connector.
-Check the PF-axis home sensor signal by using IN/OUT setting mode.
E-061
X axis A phase current offset error
-There is a trouble of current detection circuit on the PMD substrate.
-Please exchange PMD board.
-Please consult the sewing machine agent.
E-062
X axis B phase current offset error
-There is a trouble of current detection circuit on the PMD substrate.
-Please exchange PMD board.
-Please consult the sewing machine agent.
E-063
Y axis A phase current offset error
-There is a trouble of current detection circuit on the PMD substrate.
-Please exchange PMD board.
-Please consult the sewing machine agent.
E-064
Y axis B phase current offset error
-There is a trouble of current detection circuit on the PMD substrate.
-Please exchange PMD board.
-Please consult the sewing machine agent.
E-066
PMD substrate (XY axis) overcurrnet
error
-Wiring to X-motor or Y-motor is short-circuited.
-The load torque of the XY table is too large.
-Check the wiring of the X and Y motor.
-Check the sewing machine.
E-067
PMD substrate (X axis) overcurrnet
error
-Wiring to X-motor is short-circuited.
-The load torque of the XY table is too large.
-Check the wiring of the X motor.
-Check the sewing machine.
E-068
PMD substrate (Y axis) overcurrnet
error
-Wiring to Y-motor is short-circuited.
-The load torque of the XY table is too large.
-Check the wiring of the Y motor.
-Check the sewing machine.
E-069
PF axis overcurrent error
-Wiring to PF-motor is short-circuited.
-PF-axis 24V power supply cable has been disconnected. (inside of control
box)
-Check the wiring of the PF motor.
E-072
Power supply voltage decrease error
-Power supply voltage is too low than the power supply specification.
-Check power supply voltage.
E-075
TE substrate communication error
-CON2 of the SOL substrate or CON1 of the TE substrate is not inserted
firmly.
-Communication cable of the TE substrate is disconnected
-Insert connecters ( CON2 of the SOL substrate or CON1 of the TE substrate)
firmly.
-Exchange communication cable of TE substrate.
E-076
TE substrate electromagnetic valve
overcurrent error
-Output terminal and 24V terminal on the TE substrate is short-circuited.
-There is a trouble at electromagnetic valve etc. which is connected with TE
substrate.
-Total output current of the TE substrate is over rating value.
-Check output wiring from TE substrate. And remove short-circuited point.
-Exchange electromagnetic valve which is connected to TE substrate.
-Use with below the rating current value. For example, decrease number of
output, change to output device with low current value, shift on timing of
each output, change setting of the full wave on time to smaller or zero.
E-077
TE substrate 24V power supply error
-24V power supply is not supplied to the TE substrate.
-24V power supply voltage is decrease.
-Check the connection of the 24V connector of the TE substrate.
-Exchange the fuse of the TE substrate.
-Check voltage of the power supply origin.
E-078
Dynamic braking resistor over load
error
-The inertia of the sewing machine ( pulley etc.) is too large.
-Power supply voltage is too high than the power supply specification.
-Lengthened deceleration time at the machine stop.
-Check power supply voltage.
E-080
PMD substrate 12V voltage decrease
error
-External 12V power is short-circuited or decrease by the trouble of the
operation panel.
-External 12V power is short-circuited or decrease by the trouble of the SOL
substrate or the halt switch lamp.
-Remove faulty point and exchange F2 fuse on the CPU substrate.
E-081
XC-B substrate 12v voltage decrease
error
-Internal 12V power is decrease or short-circuited by trouble in the CPU
substrate or the DISP substrate.
-Internal 12V power is decrease or short-circuited by trouble in the XC-B
substrate.
-Remove faulty point and exchange F1 fuse on the CPU substrate.
E-082
USB medium overcurrent
-USB MEDIUM IS OUT OF ORDER
-NON-STANDARD USB MEDIUM BEING USED.
-CHECK USB MEDIUM
(
REFFER P.[5]-1 FOR USB MEDIUM
[17]-3
Summary of Contents for PLK-G-PAL
Page 1: ...INDUSTRIAL SEWING MACHINE MODEL PLK G PAL TECHNICAL MANUAL Operation Panel A180E606P12 ...
Page 2: ......
Page 199: ...MEMO ...
Page 200: ......