[4] - 1
[4] Names of each part, wiring and grounding
1.Front side
2.Back side
Heat sink
Power
LED(green)
Warning
LED(red)
CONR
USB
(
TYPE A
)
with Protective cap
CONS
RS-232C
(
MINI DIN
)
with Protective cap
Front panel
CONA
Operation panel
(Connect to Operation panel)
CONE
Various solenoids
(Connect to sewing machine
head section)
CONF
Spindle encoder
(Connect to spindle servo
motor)
CONG
XY axis encoder
(Connect to XY axis stepping motor)
CONH
Foot switch
(Connect to foot switch)
CONJ
XY axis stepping motor
(Connect to sewing machine
head stepping motor)
Cover installation screw
(M4 screw)
Cover
Function button
CONB
Power supply
(Connect to power switch box)
CONC
DC power for solenoid
(Connect to sewing machine head
section)
COND
Spindle servo motor
(Connect to spindle servo motor)
CONK
PF axis stepping motor
(Connect to sewing machine head
PF axis stepping motor)
Rating plate
Caution: Be sure to connect all connectors
before turning ON the power.
Connect each connector fully to
ensure sufficient contact. Refer to
“[12] Unit Wiring Diagram.”