[7] - 2
2.Timing chart for [Clamp of output ON/OFF delay setting]
Clamp input 1~8
IF1~IF8
Clamp output 1~8
OF1~OF8
3.Timing chart for [Priority of clamp]
Clamp input 1
IF1
Clamp input 2
IF2
Clamp input 3
IF3
Clamp input 4
IF4
[WHY]=[OFF]
Clamp output 1
OF1
Clamp output 2
OF2
Clamp output 3
OF3
Clamp output 4
OF4
[WHY]=[ON]
Clamp output 1
OF1
Clamp output 2
OF2
Clamp output 3
OF3
Clamp output 4
OF4
Note: [WHY]=[ON]
* The clamp input signal [IF2],[IF3],[IF4] is invalidated when clamp output 1 is not ON.
* The clamp input signal [IF2] is validated when clamp output 1 is ON.
* The clamp input signal [IF3] is validated when clamp output 2 is ON.
* The clamp input signal [IF4] is validated when clamp output 3 is ON.
1A~8A
1B~8B
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON