[8] - 4
6.Block diagram (output control section)
Physical output
O1
O2
O3
100% ON
66% ON
(
8ms ON/4ms OFF
)
66% ON
(
4ms ON/2ms OFF
)
50% ON
(
4ms ON/4ms OFF
)
50% ON
(
2ms ON/2ms OFF
)
33% ON
(
2ms ON/4ms OFF
)
17% ON
(
2ms ON/10ms OFF
)
8% ON
(
2ms ON/22ms OFF
)
Manual setting
7.Explanation of operation (output control section)
The operation of the signal output from the physical output is selected and then the signal is connected to
the output port F point.
A point
Logic operation selection
(1)
When "normal"(NO) is selected, the input waveform is connected.
(2)
When "alternate"(AL) is selected, the signal will alternately turn ON and OFF, turning ON at the
first rising edge and OFF at the next rising edge.
Input signal O1
“Normal”
A
“Alternate” A
OF
ON
Alternate
NO
AL
A
C
B
OF
ON
NO
D
ON delay
OFF delay
D
OF
ON
Full wave time
Duty
Setting time
Full wave time
Setting value x 100µs
E
Output port
Operation
selection
ON delay
OFF delay
Logic
changeover
Chopping
Setting time