[9] - 3
2.Output signal setting table
Code
Function
Specifications
OT0~OTF General purpose output 0 ~ F When IO0 is on, OT0 output at the same time (same from OT1 to OTF )
FN1~FNH Function code output 1 ~ H
When FUN1 code is read while sewing operation, FN1 output is reversed.
(same from FN2 to FNH)
OF1~OF8 Clamp output 1 ~ 8
When IF1 is on, OF1 output is reversed (same OF2 to OF8 )
NO
[NO]output
Nothing is done
T
Trimmer output
Trimming operation is done
L
Thread tension release output Thread tension release operation is done
W
Wiper output
Wiper operation is done
PF
Presser foot output
Presser foot operation is done
AFL
Pneumatic two-step switch
clamp low pressure output
When A2F input is on first time, AFL output is turned on.
Setting is effective when [ Program mode > Clamp > Pneumatic two-step
switch clamp ON/OFF (AF2)] is on.
AFH
Pneumatic two-step switch
clamp high pressure output
When A2F input is on second time, AFH output is turned on.
Setting is effective when [ Program mode > Clamp > Pneumatic two-step
switch clamp ON/OFF (AF2)] is on.
AFE
Pneumatic two-step switch
clamp excess pressure release
output
When A2F input is on third time, AFE output is turned on.
Setting is effective when [ Program mode > Clamp > Pneumatic two-step
switch clamp ON/OFF (AF2)] is on.
DHP
Home position output
When XY table is sopped on the home position, DHP output is turned on.
D2H
Second home position output
When XY table is sopped on the second home position, DHP output is turned
on.
RED
Preparation ready output
When the machine is ready state (when clamp output is on), RED output is
turned on. When machine is start sewing, RED is turned off.
DSW
Sewing in progress output
When the machine is sewing, DSW output is turned on. When machine is
stopping on the home position, DSW output is turned off.
SP
Sewing machine rotation start
output
After non stitch feed, when the sewing machine start to rotate, SP output is
turned on. When home positioning is executed, SP output is turned off.
TSE
Trimming start output
When trimming sequence (down position) is started, TSE outpu is turned on.
When trimming sequence is finished (when all the outputs of T, L and W are
turned off), TSE output is turned off.
END
Sewing completion output
When a sewing pattern operation is finished, END output is turned on.
When the next sewing is started, END output is turned off.
DCS
Halt code output
When the halt code data (USTP, DSTP) is read while sewing, DCS output is
turned on. When the machine restarts DCS output is turned off.
DST
Halt in progress output
When the machine is on halt state, DST output is turned on. When the
machine restarts DST output is turned off. However, it is not output while
stopping by the USTP code or the DSTP code.
HPO
Home returning in progress
output
While the operation of home returning by the home positioning key or HP
signal, HPO outpu is turned on.
ERR
Error output
When the error or message is displayed on the operation panel, ERR output
is turned on.
CUE
Count up completion output
When the current value of up counter is reached at counter set value, CUE
output signal is turned on. When the current value is cleared, CUE output is
turned off.
CDE
Countdown completion output When the current value of down counter is reached at 0, CDE output signal is
turned on. When the current value is initialized, CDE output is turned off.
DTS
Halt in progress output after
upper thread sensor detection
When the machine is on halt state with thread breakage, DTS output is
turned on. When the machine restarts, DTS output is turned off.
--1
DO NOT USE
DRT
Sewing machine rotation in
progress output
While the machine is rotating, DRT output is turned on.
(includes rotation in winding mode)
DN
Down position output
When the needle is down position, DN output is turned on.
CB
Buzzer output
While the buzzer in the operation panel is on, CB output is turned on.
(including count up/countdown message display)
UP
Up position output
When the needle is up position, UP output is turned on.
PWR
Power on output
While power supply is on, PWR output signal is turned on.
PUS
Presser hoot home position
output
While presser foot is on the home position, PUS output is turned on.
MSG
Message display output
When the message is displayed on the operation panel, ERR output is turned
on.
OP1
Option output 1
OP2
Option output 2
SSW
Halt signal being on output
SSW is turned on during power supply is on. However, input signal STP turns
on SSW is turned on with blinking.
O_5
DO NOT USE
Summary of Contents for PLK - G Series
Page 2: ......
Page 43: ... 12 2 ...
Page 48: ... 15 Wiring diagram inside control box 15 1 ...
Page 50: ...MEMO ...
Page 51: ......