[10] - 1
[10] What happened? Could it be an error?
When an error occurs, the error code and corresponding message appear on the operation panel. Take
a corrective action in accordance with the message. This section describes the errors and others that do
not appear on the operation panel.
[
Case1
]
Nothing appears on the operation panel when you turn the power switch ON.
(Both the front panel green (power) and red (warning) LEDs are off.)
[
Checking Items and Corrective Actions
]
Is the power switch definitely turned ON?
▪
Check the power supply connection and turn ON the power switch again.
Is the power supply connector fully connected?
▪
Check the power supply connector connection, contact state and others,
and then turn ON the power switch again.
Refer to “(12) Unit Wiring Diagram.”
Is there a blown fuse in the control box?
▪
Replace the blown fuse with a fuse of identical capacity.
Refer to page. [2]-2
Is a harness inside the control box disconnected?
▪
Check the connections of the harnesses inside the control box, and turn
ON the power switch again.
Refer to “(15) Wiring Diagram Inside Control Box”