- 40 -
7-7. Adjustment of the XY table detector
XY table detecting position is front left corner of sawing area to the needle center. At the first origin
movement when turn the machine power on, XY table moves toward above position. After detection, XY
table is back to the center of the sawing area. Before adjusting, it is necessary to remove the XY cover.
Please refer to the previous paragraph [7-6.].
NOTE When modify the home positon somewhere other than the center of sewing area, please refer to
the instructions OPERATION PANEL technical manual [17] [Easy setting 3-(8)].
Home position
Detecting positon
<5>
<2>
<4>
<1>
<3>
<5>
4
00
400
(20
0)
(
20
0
)
400
400
(200) (200)
<1>: X detect plate
<2>: X detector
<3>: Y detect plate
<4>: Y detector
<5>: Needle
<1>
<3>
<2>
<4>