9 - 7 9 - 7
MELSEC
9 UTILITY OPERATIONS
Item Content
NET mode
Selects the network where the MELSECNET/H board is connected. When "25 Mbps" is
selected in the transmission speed item above, this item cannot be selected.
Net Mode
Description
MNET/H Mode
Selected when the MELSECNET/H is connected.
MNET/10 Mode
Selected when the MELSECNET/10 is connected.
MELSECNET/H
Extended mode
1
Selected when the MELSECNET/H is connected and
MELSECNET/H Extended mode is used.
Reconnect
Designates by station type when a control station reconnects.
This item is displayed on the screen and can be selected only when the MELSECNET/H
board is a control station.
Reconnect Description
Return as control station
Causes the MELSECNET/H board to reconnect as a control
station.
Return as normal station
Causes the MELSECNET/H board to reconnect as a normal
station.
LED
Display the operation status of the MELSECNET/H board.
LED name
LED status
RUN Normal
data
link
MNG Control
station
S.MNG Sub-control
station
D.LINK During
data
link
T.PASS
Baton pass execution
2
SW.E Switch
setting error
M/S.E.
Duplicate error on station number and
control station
PRM.E. Parameter
error
CRC Code
check
error
OVER
Data entry delay error
AB.IF
All receiving data are 1.
TIME Time
over
DATA Reception
data
error
UNDER
Transmission data error
LOOP
Forward/reverse loop receiving error
SD Data
being
transmitted
RD Data
being
received
Routing Param. Setting
Button
Displays the "Routing Parameter Setting" screen.
Refer to section 9.2.4 Routing Parameter Setting operation for details.
Routing Param. Transfer
Button
Transfers the routing parameter that has been set.
Common Param. Setting
Button
Displays the "Common Parameters Setting" screen
This button is displayed only when the MELSECNET/H board is a control station.
Refer to section 9.2.5, "Common Parameters Setting Screen operation" for details.
Common Param. Transfer
Button
Transmits the set common parameters.
This button is displayed only when the MELSECNET/H board is a control station.
1: When assigning 2000 bytes or more to the number of link points sent by a station,
set all stations including control stations and normal stations to the
MELSECNET/H Extended mode.
2: If T.PASS LED flickers at uncertain intervals, take the corrective action by
referring to Section 14.4.
Summary of Contents for Q80BD-J71BR11
Page 2: ......
Page 24: ...A 22 A 22 MEMO ...
Page 50: ...4 6 4 6 MELSEC 4 FUNCTION MEMO ...
Page 92: ...6 36 6 36 MELSEC 6 PROCEDURE AND SETTINGS UP TO THE POINT OF OPERATION MEMO ...
Page 132: ...10 2 10 2 MELSEC 10 MELSEC DATA LINK LIBRARY MEMO 10 ...
Page 138: ...11 6 11 6 MELSEC 11 PROGRAMMING MEMO ...
Page 164: ...12 26 12 26 MELSEC 12 APPLICATION FUNCTIONS MEMO ...
Page 166: ...13 2 13 2 MELSEC 13 ERROR CODE MEMO 13 ...
Page 223: ......