9 - 9 9 - 9
MELSEC
9 UTILITY OPERATIONS
9.2.5 Common parameter setting screen operation
This operation sets the common parameters necessary for establishing data links.
Display is possible only when the MELSECNET/H board is in the control station.
(1) B, W setting screen
Item Content
Channel
Selects the channel (MELSECNET/H board) performing the settings.
Total Station
Input the total number of stations (including the control station) in the network that the
MELSECNET/H board is the control station for.
Monitoring Time
Sets the link scan time monitoring time.
Send Range
for Each
Station
Sta. No.
Input the station No. of the station to be set or changed.
Pairing
Set whether pairing is enabled or not.
If
"Do Pairs"
is selected, settings for the next station No. become the same as those for
the current one, being displayed with its
"
Send Range for Each Station
"
area masked.
Pairing is not available if the last station No. is selected for "Sta. No. "
LB
Input the LB (Link relay) range.
LW
Input the LW (Link register) range.
Low Speed LB Input the range of the LB (link relay) used in the low speed cyclic transmission function.
Low Speed LW Input the range of the LW (link register) used in the low speed cyclic transmission function.
Set button
Registers the set contents in each station's transmission range.
Send Range for Each Station Displays the set data contents up to the present time in one list.
Change button
Select the line to change, then when the button is clicked, the data which are registered can
be changed. (If the line to be changed is double clicked, the same operation can be
performed.)
Delete button
Select the line to change, then when the button is clicked, the data which are set can be
deleted.
Settings Clear Button
Initializes the contents of all the B and W settings registered in the "Common parameter
setting" screen.
Summary of Contents for Q80BD-J71BR11
Page 2: ......
Page 24: ...A 22 A 22 MEMO ...
Page 50: ...4 6 4 6 MELSEC 4 FUNCTION MEMO ...
Page 92: ...6 36 6 36 MELSEC 6 PROCEDURE AND SETTINGS UP TO THE POINT OF OPERATION MEMO ...
Page 132: ...10 2 10 2 MELSEC 10 MELSEC DATA LINK LIBRARY MEMO 10 ...
Page 138: ...11 6 11 6 MELSEC 11 PROGRAMMING MEMO ...
Page 164: ...12 26 12 26 MELSEC 12 APPLICATION FUNCTIONS MEMO ...
Page 166: ...13 2 13 2 MELSEC 13 ERROR CODE MEMO 13 ...
Page 223: ......