9 - 10 9 - 10
MELSEC
9 UTILITY OPERATIONS
(2) X, Y setting screen
Item Content
Channel
Selects the channel (MELSECNET/H board) performing the settings.
Block 1 setting (Block 2 setting) Switches the block that is set.
Total station
Input the total number of stations (including the control station) in the network that the
MELSECNET/H board is the control station for.
Monitoring Time
Sets the link scan time monitoring time.
I/O Master Sta.
Input the station No. of the I/O master station.
Send Range for
Each Station
Sta. No.
Input the station No. of the station to be set or changed.
Sending Range
(M L)
Assigns link devices (LX, LY) 1 to 1 between the I/O master station (M station) and other
stations.
Sending Range
(M L)
Assigns link devices (LX, LY) 1 to 1 between the I/O master station (M station) and other
stations.
Set button
Registers the set contents in each station's transmission range.
Send Range for Each Station
Displays the set data contents up to the present time in one list.
Change button
Select the line to change, then when the button is clicked, the data which are registered
can be changed. (If the line to be changed is double clicked, the same operation can be
performed.)
Delete button
Select the line to change, then when the button is clicked, the data which are set can be
deleted.
Setting Clear Button
Initializes the contents of all the X and Y settings registered in the "Common parameter
setting" screen.
Summary of Contents for Q80BD-J71BR11
Page 2: ......
Page 24: ...A 22 A 22 MEMO ...
Page 50: ...4 6 4 6 MELSEC 4 FUNCTION MEMO ...
Page 92: ...6 36 6 36 MELSEC 6 PROCEDURE AND SETTINGS UP TO THE POINT OF OPERATION MEMO ...
Page 132: ...10 2 10 2 MELSEC 10 MELSEC DATA LINK LIBRARY MEMO 10 ...
Page 138: ...11 6 11 6 MELSEC 11 PROGRAMMING MEMO ...
Page 164: ...12 26 12 26 MELSEC 12 APPLICATION FUNCTIONS MEMO ...
Page 166: ...13 2 13 2 MELSEC 13 ERROR CODE MEMO 13 ...
Page 223: ......