12 - 3 12 - 3
MELSEC
12 APPLICATION FUNCTIONS
12.2.1 Send range settings
Each station's send range of link devices (low-speed LB, low-speed LW) is assigned to
the extended area (2000 to 3FFF) in 16-point units for LB (start : 0 to end
F) and in one-point units for LW.
Each station's send range can also be assigned using a random station number
assignment sequence.
(1) Device range
MELSECNET/H Board LB
0
H
2000
H
3FFF
H
(8192)
(16383)
Normal cyclic transmission area
Extended function area
(2) Screen settings
This shows in the case where 768 points of the transmission range for each
station is assigned to (Low Speed LB, Low Speed LW) in the "Common
parameter setting (B, W Setting)" screen in the MNETH utility.
Send range
(2000 to 3FFF)
POINT
(1) The total of the send ranges per station must not exceed 2000 bytes in the low-
speed cyclic transmission. (The send range for the normal cyclic transmission
is not included.)
(2) The LX and LY cannot be set as low-speed cyclic devices.
(3) Low-speed cyclic transmission function cannot be used during
MELSECNET/10 mode.