13.1 List of Error Messages in CC IE Control Utility
13.1.1 Error messages displayed on the board information screen
13
- 2
13.1.1 Error messages displayed on the board information screen
(1) Board list screen (start screen)
(2) Channel number confirmation screen
(3) Board detail information
Error message
Corrective action
Only one CC IE Control utility can be started.
CC IE Control utility has already been started.
The CC IE Control utility has already been activated.
Execute after completing the activated CC IE Control utility.
Failed to open the Help file.
The installation of SW1DNC-MNETG-B may be failed.
Reinstall SW1DNC-MNETG-B.
Failed to start up the Device monitor utility.
The installation of SW1DNC-MNETG-B may be failed.
Reinstall SW1DNC-MNETG-B.
Driver is not started.
Check if the driver is started.
A CC-Link IE Controller Network board is not mounted.
Mount a board then start utility.
• Check if the CC-Link IE Controller Network board is
mounted.
• Start the CC IE Control utility after mounting the CC-Link IE
Controller Network board.
Failed to read the version information.
The installation of SW1DNC-MNETG-B may be failed.
Reinstall SW1DNC-MNETG-B.
Error message
Corrective action
LED cannot be displayed because of boardXX is bus I/F test.
Please set the mode besides bus I/F test.
Set the mode other than bus I/F test.
Error message
Corrective action
It failed in the save of SB/SW. There is a possibility of failing
in the installation.
The installation of SW1DNC-MNETG-B may be failed.
Reinstall SW1DNC-MNETG-B.
It failed in the acquisition of SB/SW.
It is not possible to preserve it in the file.
The installation of SW1DNC-MNETG-B may be failed.
Reinstall SW1DNC-MNETG-B.
The file path cannot be set exceeding 255 characters.
Please select it again.
Set the file path within 255 characters.
Read-only save target.
Please confirm save target and execute it again.
Cancel the write protection at save location.
It failed in the save of the SB/SW file.
Confirm the position of the save file.
Change the file to be specified.
Failed to read the data.
• Restart the CC IE Control utility.
• The installation of SW1DNC-MNETG-B may be failed.
Reinstall SW1DNC-MNETG-B.
The board is reset. All right?
• Restart the CC IE Control utility.
• The installation of SW1DNC-MNETG-B may be failed.
Reinstall SW1DNC-MNETG-B.
Disk space of destination is not enough.
Please specify other destination.
Reserve the disc space of the write destination.