3-66
Installing the solenoid valve set
3Installing the option devices
4) Connect the tool prepared by the customer with solenoid valve port A and B.
Please prepare the air hoses to connect by customer. Install attached plugs to the port A/B couplings that
are not used for the solenoid valve set.
shows the relation between hand condition and port number.
This completes the procedure to install the solenoid valve set.
Table 3-7 : Solenoid valve ports and hand number
Hand
Hand condition
Port number
The solenoid
valve set in use
Hand 1
OPEN
1
One set
CLOSE
2
Hand 2
OPEN
3
Two sets
CLOSE
4
Hand 3
OPEN
5
Three sets
CLOSE
6
Hand 4
OPEN
7
Four sets
CLOSE
8
Port number
B port
2
4
6
8
A port
1
3
5
7