5 Maintenance and Inspection
Resetting the origin 5-125
5.6.4 Recording the origin data
When the origin has been set with the jig method, record that origin data on the origin data label. With this, the ori
-
gin can be set with the origin data input method the next time.
Confirm the origin data on the teaching pendant screen (origin data input screen). The origin data label is enclosed
with the arm or attached on the back of the CONBOX cover.
The teaching pendant operation method and CONBOX cover removal method for confirming the origin data is the
same as the methods for setting the origin with the origin data input method. Refer to
origin with the origin data input method"
, and write the origin data displayed on the teaching pendant onto the ori
-
gin label.
(1)
Confirming the origin data label
Remove the CONBOX cover.
Refer to
Page 82, "5.3.2 Installing/removing the cover"
, and remove the CONBOX cover.
(2) Confirming the origin data
Confirm the value displayed on the teaching pendant's Origin Data Input screen.
Refer to
Page 20, "2.3.2 Setting the origin with the origin data input method", "(5)Inputting the origin data"
display the Origin Data Input screen on the teaching pendant display screen.
(3) Recording the origin data
Write the origin data displayed on the teaching pendant to the origin data label attached to the back of the CON
-
BOX cover. Refer to
Page 20, "Fig.2-11 : Origin data label (an example)"
Correspondence of origin data label and axis"
for details on the origin data label.
(4) Installing the cover
Install the CONBOX cover removed in step
"(1)Confirming the origin data label"
above.
Refer to
Page 82, "5.3.2 Installing/removing the cover"
, and replace the CONBOX cover.
This completes the recording of the origin data.