─ 85 ─
11-3 VL-500CZPVU-L type,
VL-500CZPVU-R type
Note:
The following procedure applies to the
VL-500CZPVU-L
type. For VL-500CZPVU-R type, the compo-
nents are placed in the right-left opposite positions.
(1) Turn off the power supply
[1] Stop the operation.
[2] Turn off the circuit breaker on the distribution board.
(2) Remove the heat exchanger
... Refer to 11-1 (2).
Heat exchanger
Mark line
PCB plate
Assembly precaution
Insert the heat exchanger to the mark line on the PCB
plate.
Bypass plate
(3) Remove the PCB cover
[1] Remove the heat exchanger. ... Refer to (2).
[2] Remove the bypass plate.
a. Remove the screws.
(2 screws: Spl screw PTT 4X14, indicated by )
Tightening torque
: 1.2 ± 0.2 N.m
b. Disengage the bypass plate from the boss part on the upper side.
Bypass plate
Boss part
Assembly precaution
When installing the bypass plate, tighten the upper screw (to the boss part) before tightening the lower
screw.