Page 6-7
Arc Protect
The Arc Protect circuit is also shown in Figure 6-8.
It does not control the logic at the X-RAY input to
the uPC, but if activated, the symptom is similar to
X-RAY Protect operation, the set switches OFF.
However, if the Arc Protect circuit shuts the set OFF,
the set cannot be switched back ON unless AC power
is removed, and then reapplied to the set.
If an arc occurs, there is a momentary sudden de-
crease in the voltage at pin 8 of the Flyback. The
sudden drop in voltage turns Q523 ON. The con-
duction of Q523 turns Q524 ON, which holds the
base of Q523 LOW. When Q523 conducts it turns
the set OFF by pulling the P-ON command to the
power supply LOW.
Since the circuit latches ON when activated, the set
cannot be switched back ON. AC Power must be
removed, allowing C593 to discharge, before the set
can be turned back ON.
To check the Arc Protect circuit, momentarily short
TP1 to ground. The set must automatically switch
OFF. The TV should not switch ON unless AC power
is removed then reapplied.