102
-
3.2 Indoor unit
(a) Ceiling cassette-4 way type (FDT)
Models All models
C
P
JF
0
0
0
Z
0
5
3
BK
t°
Relay for DM
X4
Drain motor
Fan motor
DM
Louver motor
Float switch
LM1〜4
FS
Fuse
F200−203
Connector
CNA〜Z
LED・2
Operation check, Drain motor test run
Thermistor(Remote controller)
Control PCB
Power PCB
Model capacity setting
SW6
Terminal block(Power source)
TB1
TB2
Indication lamp
LED・3
Stepping motor
SM
SW1
SW2
Indoor unit address : tens place
SW3
SW4
Automatic adjustment/Fixed previous
SM
t°
t°
1
2
3
4
5
6
t°
1
2
RD
1
2
WH
1
Y
OR
BL
BR
M
2
3
4
5
6
XR1
XR2
XR3
XR4
XR5
Option
1
2
3
4
5
6
+12
SW1 SW2 SW3 SW4
SW6
SW5
SW7
LED・2 LED・3
X
Y
A
B
1
3
1
2
X
Y
t°
Remote
TB2
WH
BK
BL
RD
RD
RD
RD
RD
RD
1
2
3
4
5
1
2
3
4
5
CNW3
RD
CNW2
RD
BL
BL
BL
BL
BL
2
1
3
4
5
1
2
3
4
5
CNW4
BL
CNW1
BL
CNB
WH
CNK1
WH
CNN
Y
CNH
BK
CNI
BL
CNA
RD
CNT
BL
L
N
WH
RD
F200(3.15A)
F201(3.15A)
M
1 4 5 6 7
F202
(1.0A)
F203
(0.16A)
CNM
WH
X4
3
1
CNW0
WH
1 3
5
Power source
TB1
M
1〜
CNR
WH
DM
WH
RD
FS
BK
BK
BK
BK
BK
M
BK
BK
BK
BK
BK
1
2
3
4
5
1
2
3
4
5
1
2
3
4
5
LM1
BK
BK
BK
BK
BK
M
BK
BK
BK
BK
BK
6
7
8
9
10
1
2
3
4
5
6
7
8
9
10
LM2
RD
RD
RD
RD
RD
M
BK
BK
BK
BK
BK
11
12
13
14
15
1
2
3
4
5
11
12
13
14
15
LM3
RD
RD
RD
RD
RD
M
BK
BK
BK
BK
BK
16
17
18
19
20
1
2
3
4
5
16
17
18
19
20
LM4
CNJ2
WH
CNJ
WH
■mark
Closed−end connector
BK
Power
(20S)
(SVH)
(SVG)
(SVE)
XB1
XB2
XB3
XB4
1
2
3
4
5
+12
CNT2
RD
CNK2
Superlink(spare)
JSL1
Live Superlink terminal setting(for spare)
JSL1
Y
Y
Y/GN
SW5−1
SW5−2
SW7−1
Earth
CNU
BL
220ー240V〜50Hz
220V〜60Hz
Signal line
between indoor units
FM
I
Th
C
Th −A
Th −R1
I
Th −R2
Th −R3
FM
Th −A
Th −R1,2,3
Th
I
I
I
C
I
I
Indication lamp(Red−Inspection)
Indoor unit address : ones place
Outdoor unit address : tens place
Outdoor unit address : ones place
version of Superlink protocol
Indoor unit address : hundreds place
Terminal block(Signal line)(口mark)
Thermistor(Return air)
Thermistor(Heat exchanger)
BK
BK
BK
BK
BK
BK
BK
RD
RD
For Heat recovery
3−pipe systems
controller
Signal line
Circuit
Y/GN
between indoor units
Power source line
line
Single−phase
3−pipe systems
controllerof heat recovery
BK
BL
BR
OR
Black
Blue
Brown
Orange
RD
WH
Y
Y/GN
Red
White
Yellow
Yellow/Green
I
Y / G N
RD
BL
BR
OR
WH
(Shielded cord)
(Operation)
(Heating)
(Operation)
(Thermo ON)
(Remote operation input
: volt−free contact)
Power source
(for electronic expansion valve)
(Green−Normal operation)
(口mark)
Connector for branching
Y/GN
Y/GN
Y/GN
1. indicates wiring on site.
Color Marks
Mark
Color
Mark
Color
2.Use twin core cord(0.75〜1.25mm )at signal line between indoor unit
2
and outdoor unit, and signal line between indoor units.
3.Use twin core cord(0.3mm )at remote controller line.
2
See spec sheet of remote controller in case that the total length is more
than 100m.
4.Do not put signal line and remote controller line alongside power source line.
Notes
5 or 6 wires
Summary of Contents for 112KXE6
Page 105: ... 101 Model FDC335KXE6 A PCB003Z035 shows local wining ...
Page 134: ... 130 PJF012D003 ...
Page 135: ... 131 ...
Page 139: ... 135 PJA012D751 b ...
Page 140: ... 136 ...
Page 206: ... 202 2 model type DIS model type HEAD ...
Page 207: ... 203 2 2 ...
Page 208: ... 204 2 2 2 2 2 ...