(c) Ceiling cassette-2 way type (FDTW)
Models FDTW28KXE6, 45KXE6, 56KXE6
B
P
JB
0
0
1
Z
5
6
0
H
W
Y
Y
Connector for branching
controller of heat recovery
3−pipe systems
BK
BL
BR
GR
Black
Blue
Brown
Gray
OR
Orange
RD
Red
WH
White
Y
Yellow
Y/GN Yellow/Green
WH
CNA
CNN
CNH
CNW2
Earth
1
2
Remote
t°
TB2
BL
RD
1
3
WH
BK
CNK1
CNB
XR1
XR2
XR3
XR4
XR5(Remote operation input:
Option
1
2
3
4
5
6
+12
CNT
BL
(Operation)
(Heating)
(Thermo ON)
(Inspection)
Superlink(spare)
JSL1
For Heat recovery
(20S)
(SVH)
(SVG)
(SVE)
XB1
XB2
XB3
XB4
1
2
3
4
5
+12
CNT2
RD
Control PCB
F(0.16A)
volt−free contact)
controller
3−pipe systems
Color Marks
Mark
Color
Notes 1. indicates wiring on site.
2. Use twin core cable(0.75〜1.25mm )at signal line between indoor unit
2
and outdoor unit, and signal line between indoor units.
3. Use twin core cable(0.3mm
2
)at remote controller line. See spec sheet
of remote controller in case that the total length is more than 100m.
4. Do not put signal line and remote controller line alongside power source line.
Signal line(Shielded cord)
Signal line
between indoor units
I
I
I
I
I
Relay for FM
Thermistor(Remote controller)
Thermistor(Heat exchanger )
Thermistor(Return air)
Model capacity setting
SW6
Thc
Th −R1,2,3
Th −A
X1〜3,6
Operation check, Drain motor test run
TB2
Terminal block(Signal line)(□mark)
Tr
SW7−1
Transformer
Relay for LM
Relay for DM
X4
X5
TB1
Terminal block(Power source)(□mark)
I
I
I
I
FS
CF
DM
FM
Float switch
Drain motor
Capacitor for FM
Fan motor(with thermostat)
I
F
Fuse
Connector
CNA〜Z
1
I
1
LS
LM
Louver switch
Louver motor
Indoor unit address: tens place
SW1
SM
Stepping motor
Indoor unit address: ones place
SW2
Indication lamp(Red−Inspection)
Indication lamp(Green−Normal operation)
LED・3
LED・2
SW3
SW4
Outdoor unit address: tens place
Outdoor unit address: ones place
SW5−1
Automatic adjustment/Fixed previous
SW5−2
Indoor unit address: hundreds place
Live Superlink terminal setting(for spare)
JSL1
version of Superlink protocol
(for electronic expansion valve)
CNJ
CNF1
I
CF
FM 1
LM
WH
BK
BL
CNS
X1
3
UH
BR
WH
CNM3
C
WH
1
X6
M
H
BK
BL
5
7
L
RD
9
X3
X2
BK
LS
3
OR
CNJ2
CNR
3
BR
1
WH
WH
1
WH
X4
X5
CNI
BL
RD
RD
BL
WH
CNW1
220ー240V
CNS2
WH
BK
Tr
Power source
TB1
WH
RD
220ー240V〜 50Hz
Single−phase
CNW0
WH
CNU
WH
RD
1
3
RD
RD
BL
CNR2
DM
BL
1〜
M
FS
M
1〜
1〜
M
BK
RD RD BR BR
1 2 3 4 5 6
RD
Th −R1
Th −A
Th −R2
BK
t°
t°
1
2
3
4
Th −R3
5
6
1
2
t°
GR
t°
F(3.15A)
Y/GN
M
WH Y OR BL BR RD
BK
BK
Thc
A B
X Y
X Y
WH
WH
SM
19V
24V
5
I
1
between indoor units
BK
BK
BK
GR
BK
BK
line
Power source
Y
Power source line
F(3.15A)
220V〜 60Hz
BK
BK
Y/GN
LED・2
SW2
SW6
SW5
SW7
LED・3 SW1
SW3 SW4
CNK2
L
N
5 or 6 wires
Summary of Contents for 112KXE6
Page 105: ... 101 Model FDC335KXE6 A PCB003Z035 shows local wining ...
Page 134: ... 130 PJF012D003 ...
Page 135: ... 131 ...
Page 139: ... 135 PJA012D751 b ...
Page 140: ... 136 ...
Page 206: ... 202 2 model type DIS model type HEAD ...
Page 207: ... 203 2 2 ...
Page 208: ... 204 2 2 2 2 2 ...