108
-
Model FDTS71KXE6
A
P
JC
0
0
1
Z
1
9
6
BK
BL
BR
GR
Black
Blue
Brown
Gray
P
Pink
RD
Red
WH
White
Y
Yellow
Y/GN Yellow/Green
LB
LG
Light Blue
Light Green
Orange
OR
Connector for branching
controller of heat recovery
3−pipe systems
5 or 6 wires
I
I
I
I
Relay for FM
Thermistor(Remote controller)
Thermistor(Heat exchanger )
Thermistor(Return air)
Model capacity setting
SW6
Thc
Th −R1,2,3
Th −A
X1〜3,6
Operation check, Drain motor test run
TB2
Terminal block(Signal line)(□mark)
Tr
SW7−1
Transformer
Relay for LM
Relay for DM
X4
X5
TB1
Terminal block(Power source)(□mark)
I
I
I
I
FS
CF
DM
FM
Float switch
Drain motor
Capacitor for FM
Fan motor(with thermostat)
I
F
Fuse
Connector
CNA〜Z
1,2
I
1,2
LS
LM
Louver switch
Louver motor
Indoor unit address: tens place
SW1
SM
Stepping motor(for electronic expansion
Indoor unit address: ones place
SW2
Indication lamp(Red−Inspection)
Indication lamp(Green−Normal operation)
LED・3
LED・2
SW3
SW4
Outdoor unit address: tens place
Outdoor unit address: ones place
SW5−1
Automatic adjustment/Fixed previous
SW5−2
Indoor unit address: hundreds place
Live Superlink terminal setting(for spare)
JSL1
version of Superlink protocol
■mark
Closed−end connector
valve)
I
X1
3
UH
BR
WH
C
WH
1
1
X6
M
H
BK
BL
5
7
L
RD
9
X3
X2
3
TB1
LED・2
SW6
SW5
SW7
LED・3
WH
WH
WH
XR1
XR2
XR3
XR4
1
2
3
4
5
6
+12
t°
t°
t°
t°
CNN2
BK
BL
BL
BL
(20S)
(SVH)
(SVG)
(SVE)
XB1
XB2
XB3
XB4
1
2
3
4
5
+12
Th −R1
Th −A
Th −R2 Th −R3
1
2
t°
TB2
1
3
Y/GN
BK
BK
GR
GR
BK
BK
BK
BK
BK
BK
Y
BK
BL
RD
WH
WH
BL
BL
BL
RD
WH
BK
WH
WH
WH
WH
BK
BL
BK
BK
WH
RD
RD
WH
RD
WH
RD
WH
WH
Y/GN
Y/GN
CNM3
L
N
19V
24V
CNF2
CNF1
CF
CF
CNR
3
1
X4
CNW1
FS
M
1〜
M
1〜
5
5
5
5
I
1
I
2
1
2
3
4
5
6
1
2
3
CNJ2
1
X5
M
1〜
LM
LS
CNU
WH
RD
1 2 3 4 5 6
M
SM
CNR2
DM
1〜
M
CNL6
1
3
2
5
4
7
6
9
8
10 11
CNL4
CNL2
CNL1
CNL5
CNL3
A B
X Y
X Y
Y
Y
WH
between indoor units
Power source line
220ー240V〜 50Hz
(Single−phase)
Power source
220V〜 60Hz
Power source
Thc
WH
OR
BR
BL
Y
LG
P
BK
RD
GR
LB
WH Y OR BL BR RD
WH Y OR BL BR RD
RD
RD
OR
OR
BK
BK
BK
BK
RD
RD BR BR
F(3.15A)
F(3.15A)
CNW2
CNN
CNH
CNT
CNT2
CNK1
CNB
CNI
CNS
RD
RD
RD
RD
CNI2
CNJS
BK
BK
CNS3
BK
BK
OR
WH
OR
WH
BL
BL
BR
WH
CNA
CNW0
line
CNA2
220ー240V
Tr
I
FM 1
I
FM 2
JSL1
F(0.16A)
Color Marks
Mark
Color
For Heat recovery
3−pipe systems
XR5(Remote operation input:
volt−free contact)
(Operation)
(Heating)
(Thermo ON)
(Inspection)
Option
Earth
Superlink(spare)
Control PCB
Remote
controller
Notes 1. indicates wiring on site.
2. Use twin core cable(0.75〜1.25mm )at signal line between indoor unit
2
and outdoor unit, and signal line between indoor units.
3. Use twin core cable(0.3mm
2
) at remote controller line. See spec sheet
of remote controller in case that the total length is more than 100m.
4. Do not put signal line and remote controller line alongside power source line.
Signal line(Shielded cord)
Signal line
between indoor units
CNK2
SW2
SW1
SW3 SW4
Summary of Contents for 112KXE6
Page 105: ... 101 Model FDC335KXE6 A PCB003Z035 shows local wining ...
Page 134: ... 130 PJF012D003 ...
Page 135: ... 131 ...
Page 139: ... 135 PJA012D751 b ...
Page 140: ... 136 ...
Page 206: ... 202 2 model type DIS model type HEAD ...
Page 207: ... 203 2 2 ...
Page 208: ... 204 2 2 2 2 2 ...